Esophageal Doppler Monitoring (Deltex CardioQ Esophageal Doppler Monitor, ODM) is used to manage patients' fluid therapy by non-invasively measuring continuous cardiac output with an esophageal probe. The aim of this study was to compare the effects of patient position changes on cardiac indices and vital signs in patients who underwent major abdominal cancer surgery with laparoscopic and open surgery using ODM.
Patients who underwent major abdominal cancer surgery using ODM in the operating room of our hospital between November 2021 and November 2022 were identified from the Anesthesiology Clinic records and examined according to whether they were operated with open or closed (laparoscopic) methods. Demographic data, vital signs, amount of bleeding, type and amount of fluid administered, and the results of cardiac index measurements performed with the ODM device in the supine and trendelenburg positions (45 degrees) were analyzed. Parameters recorded with the ODM device; CO: Cardiac output, FTc: Flow time corrected, PV: Peak velocity, SD: Stroke distance.
Study Type
OBSERVATIONAL
Enrollment
80
Cardiac indices in supine and trendelenburg position in patients undergoing open or laparoscopic major cancer surgery
Dr.Abdurrahman Yurtaslan Ankara Oncology Train and Research Hospital
Ankara, Turkey (Türkiye)
Cardiac Output
Measurement of cardiac output with the oesophageal doppler device immediately after induction of anaesthesia and in the middle of the case in both supine and trendelenburg position of the patient to see whether there is a significant difference in positional change.
Time frame: Immediately after induction of anaesthesia and at any stable time during the case
Stroke Volume
Measurement of cardiac output with the oesophageal doppler device immediately after induction of anaesthesia and in the middle of the case in both supine and trendelenburg position of the patient to see whether there is a significant difference in positional change.
Time frame: Immediately after induction of anaesthesia and at any stable time during the case
Flow time corrected
Measurement of cardiac output with the oesophageal doppler device immediately after induction of anaesthesia and in the middle of the case in both supine and trendelenburg position of the patient to see whether there is a significant difference in positional change.
Time frame: Immediately after induction of anaesthesia and at any stable time during the case
Peak Velocity
Measurement of cardiac output with the oesophageal doppler device immediately after induction of anaesthesia and in the middle of the case in both supine and trendelenburg position of the patient to see whether there is a significant difference in positional change.
Time frame: Immediately after induction of anaesthesia and at any stable time during the case
Stroke Distance
Measurement of cardiac output with the oesophageal doppler device immediately after induction of anaesthesia and in the middle of the case in both supine and trendelenburg position of the patient to see whether there is a significant difference in positional change.
Time frame: Immediately after induction of anaesthesia and at any stable time during the case
Mean arterial pressure
Measurement of cardiac output with the oesophageal doppler device immediately after induction of anaesthesia and in the middle of the case in both supine and trendelenburg position of the patient to see whether there is a significant difference in positional change.
Time frame: Immediately after induction of anaesthesia and at any stable time during the case
Pulse
Measurement of cardiac output with the oesophageal doppler device immediately after induction of anaesthesia and in the middle of the case in both supine and trendelenburg position of the patient to see whether there is a significant difference in positional change.
Time frame: Immediately after induction of anaesthesia and at any stable time during the case
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.