The goal of this clinical trial is to learn about the influence of artificial tears on measurements of healthy eyes with three different devices. The main questions it aims to answer are: * Do artificial tears alter the measurements of the corneal surface * Is there a difference between the devices used in this study This is relevant because high quality measurements improve the postoperative outcome after cataract surgery.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
DIAGNOSTIC
Masking
NONE
Enrollment
145
Application of low viscosity artificial tears (Artelac EDO). The active ingredient is hypromellose (1.92 mg per 0.6 ml container).
Before artificial tear application, 2 baseline measurements were taken of the cornea without any intervention
Goethe University Hospital
Frankfurt am Main, Hesse, Germany
Does the application of artificial tears (Artelac EDO) alter the measurement of the anterior surface of the cornea (K mean in Diopters) using devices that either use keratometry or Scheimpflug-technology (IOL Master 700, Pentacam AXL or Galilei G6)
Difference of measurement of the mean corneal refractive power in diopters before artificial tear application and after artificial tear application using one of three devices (IOL Master 700, Pentacam AXL or Galilei G6)
Time frame: Comparison between the baseline measurements and the measurements 30 seconds after artificial tear application
Is there any difference in anterior corneal refractive power measurements (K mean in Diopters) between the three different devices (IOL Master 700, Pentacam AXL, Galilei G6) after artificial tear (Artelac EDO) application?
Difference of measurement of the mean corneal refractive power in diopters before artificial tear (Artelac EDO) application and after artificial tear application between the three devices (IOL Master 700 using Keratometry, Pentacam AXL and Galilei G6 using Schmeipflug technology)
Time frame: Comparison between the baseline measurements and the measurements 30 seconds after artificial tear application
Does the application of artificial tears (Artelac EDO) alter the anterior astigmatism measurements (in diopters) using devices that either use keratometry or Scheimpflug-technology (IOL Master 700, Pentacam AXL or Galilei G6)
Difference of measurement of the mean corneal astigmatism in diopters before artificial tear (Artelac EDO) application and after artificial tear application using three different devices (IOL Master 700, Pentacam AXL and Galilei G6)
Time frame: Comparison between the baseline measurements and the measurements 30 seconds after artificial tear application
If there is an influence of artificial tears (Artelac EDO) on the measurement of the anterior surface of the cornea (K mean in Diopters) using the devices (IOL Master 700, Pentacam AXL or Galilei G6), how long does it last (in minutes)?
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
How long does the difference of mean corneal refractive power in diopters before artificial tear (artelac ego) application and after artificial tear application last
Time frame: Comparison between the baseline measurements and the measurements up to 10 minutes after artificial tear applications