A prospective, multicenter, randomized clinical trial in two tertiary pediatric emergency department. It will assess, amongst pediatric healthcare teams, whether the use of augmented reality supportive devices improves adherence to American Heart Association (AHA) advanced life support guidelines and performance, while reducing medication errors, when compared to groups using the AHA pocket reference card (control) during standardized, simulation-based, pediatric in-hospital cardiac arrest (IHCA) scenarios. Seventy participants will be randomized. The primary endpoint is the time to first dose of epinephrine.
Each year, thousands of children experience cardiopulmonary arrests (CA), requiring immediate and accurate resuscitation for favorable outcomes. However, adherence to American Heart Association (AHA) advanced life support guidelines remains suboptimal, hindered by cognitive and communication challenges in high-stress cardiopulmonary resuscitation (CPR) situations. To address this problem, will assess a novel augmented reality (AR)-assisted digital health solution designed to offer personalized, real-time decision support for team leaders and medication nurses, while concurrently optimizing team situational awareness and communication by projecting a dynamic care roadmap onto a large screen in the resuscitation room, controlled via a mobile tablet app. The solution comprises three essential digitally interconnected elements: 1) a mobile app that presents clinical algorithms alongside patient data, guiding the resuscitation team through step-by-step procedures, 2) a giant screen that displays real-time patient information and task progress for the entire resuscitation team, and 3) augmented reality devices worn by team members, providing role-specific guidance and decision support based on data collected by the app. In this trial, we will assess, amongst pediatric healthcare teams, whether the use of the AR-assisted tool improves adherence to AHA resuscitation guidelines and performance, while reducing medication errors, when compared to groups using the AHA pocket reference card (control) in an open-label, prospective, multicenter, cluster randomized (1:1 ratio) clinical trial. Sixty physicians and nurses will be recruited to form teams of 7, each managing simulated pediatric in-hospital cardiac arrest (IHCA) scenarios using either an AR-assisted tool or conventional AHA pocket reference cards. Each team will comprise three participants assigned to the roles of 1) Team Leader (a physician), 2) Charting Nurse, and 3) Medication Nurse, with two CPR Providers, an Airway Provider, and a Bedside Provider roles filled by research actors. All participants and actors will view a CPR Coach orientation video to ensure understanding of the CPR Coach and Provider functions The primary outcome is the time in seconds to first dose of epinephrine. Secondary outcomes are times to CPR initiation, defibrillation, drug delivery, airway securing, the rate of medication errors, CPR pause frequency, CPR quality (excellent CPR percentage, chest compression fraction, peri-shock pause duration), provider workload (NASA-TLX survey) and stress (STAI), user experience (UEQ), system usability (SUS), and technology acceptance (UTAUT).
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
OTHER
Masking
SINGLE
Enrollment
54
Participants will view a standardized orientation video describing the clinical environment, equipment, manikin functionality, and participant roles, followed by a 15-minute table-top practice simulation where participants have opportunity to use the assigned intervention by running through a cardiac arrest scenario. Then, participants will undertake a 20-minute tightly standardized cardiac arrest simulation scenario using a high-fidelity pediatric manikin. The scenarios will be videotaped from a bird's-eye view angle at the foot of the bed, along with three action video cameras worn by the participants, and positioned within the room. Following completion of the scenario, participants will fill out five surveys (see secondary outcomes), which together take about 15 minutes to fill.
Participants will view a standardized orientation video describing the clinical environment, equipment, manikin functionality, and participant roles, followed by a 15-minute table-top practice simulation where participants have opportunity to use the assigned intervention by running through a cardiac arrest scenario Then, participants will undertake a 20-minute tightly standardized cardiac arrest simulation scenario using a high-fidelity pediatric manikin. The scenarios will be videotaped from a bird's-eye view angle at the foot of the bed, along with three action video cameras worn by the participants, and positioned within the room. Following completion of the scenario, participants will fill out five surveys (see secondary outcomes), which together take about 15 minutes to fill.
Alberta Children's Hospital
Calgary, Alberta, Canada
Geneva Children's Hospital, Geneva University Hospitals
Geneva, Switzerland
Time to first dose of epinephrine
The primary outcome is the time in seconds to first dose of epinephrine administration
Time frame: 20 minutes
Time to initiation of cardiopulmonary resuscitation
The time in seconds from the investigator's clinical statement to initiation of chest compression
Time frame: 20 minutes
Time to defibrillation
The time in seconds from the investigator's clinical statement to each manual defibrillator shock delivery
Time frame: 20 minutes
Time to delivery of epinephrine
The time in seconds from the investigator's clinical statement to intravenous injection of epinephrine to treat underlying condition
Time frame: 20 minutes
Time to delivery of amiodarone
The time in seconds from the investigator's clinical statement to intravenous injection of amiodarone to treat underlying condition
Time frame: 20 minutes
Time to secure definitive airway
The time in seconds from the investigator's clinical statement to the successful establishment of a definitive airway via endotracheal intubation
Time frame: 20 minutes
Medication dosage errors
Errors in drug dose administration (milligrams), defined as a deviation from the correct weight-based dose of more than 10% according to predefined, expert consensus-based criteria, will be measured (i.e., absolute and percentage deviation) in each allocation group as a deviation from the 2020 AHA Pediatric Advanced Life Support cardiac arrest algorithm.
Time frame: 20 minutes
Types of Medication Errors
The nature of the error type will be recorded, such as incorrect drug selection (i.e., administering the wrong medication), administration timing errors (i.e., administering the medication at the wrong time during the resuscitation process), labeling errors (i.e., misinterpreting or misreading the medication label), equipment-related errors (i.e., issues related to the functioning or availability of equipment needed for drug administration \[e.g., syringe malfunction\]), and documentation errors (i.e., inaccurate or incomplete recording of medication administration details)
Time frame: 20 minutes
Frequency of Medication Errors
Number of times medication errors occur during the cardiac arrest scenario
Time frame: 20 minutes
Frequency of pauses in cardiopulmonary resuscitation
Number of times of cardiopulmonary resuscitation pauses during the cardiac arrest scenario
Time frame: 20 minutes
Duration of pauses in cardiopulmonary resuscitation
The total time in seconds of cardiopulmonary resuscitation pauses during the cardiac arrest scenario
Time frame: 20 minutes
Causes of pauses in cardiopulmonary resuscitation
The causes leading to resuscitation interruptions will be identified and documented
Time frame: 20 minutes
Cardiopulmonary resuscitation quality: Percentage of overall excellent cardiopulmonary resuscitation
The proportion of cardiopulmonary resuscitation administrations that meet the predefined AHA standards for high-quality resuscitation techniques.
Time frame: 20 minutes
Cardiopulmonary resuscitation quality: Chest compression fraction
The fraction of time in seconds that chest compressions are being performed over the total cardiopulmonary resuscitation duration
Time frame: 20 minutes
Cardiopulmonary resuscitation quality: Peri-shock pause duration
The length of time in seconds between the cessation of chest compressions and the delivery of a defibrillation shock during cardiopulmonary resuscitation
Time frame: 20 minutes
Provider workload (NASA-TLX)
Assessed via NASA-TLX. It measures mental burden across 6 dimensions: mental, physical, temporal demands, performance, effort, and frustration. Scores range from 0 to 100 in 5-point increments (0: no task load; 100: maximal task load). Participants rate each dimension based on their perceived workload. To combine the dimensions into a final score, a weighting procedure is used. This involves comparing each dimension with every other dimension to determine its relative importance in influencing workload. Participants select the dimension that contributes most to workload in each pair of comparisons. Each dimension is then weighted based on the participant's selections, with higher weights given to dimensions that are chosen more frequently. The weighted scores for each dimension are summed to calculate the overall score, which ranges from 0 (minimal task load) to 100 (maximal task load)
Time frame: 15 minutes
User Experience Questionnaire (UEQ)
UEQ is a widely used questionnaire to measure the subjective impression of users towards the user experience of products. The UEQ is a semantic differential with 26 items that are grouped into six scales (Attractiveness, Perspicuity, Efficiency, Dependability, Stimulation, and Novelty). Each scale represents a distinct usability quality aspect. The minimum value is 0 (i.e., the worst user experience) and the maximum value is 100 (i.e., the best user experience). Participants will be asked to complete the UEQ directly after they have completed the resuscitation scenario
Time frame: 15 minutes
System Usability Scale (SUS)
SUS is a widely used questionnaire for assessing the perceived usability of a system or product. The SUS consists of a 10-item questionnaire where users rate their agreement or disagreement with a series of statements regarding the usability of a system using a 5-point Likert scale (1 to 5). The minimum value is 0 (i.e., the system is not usable) and the maximum value is 100 (i.e., the system is absolutely usable). Participants will be asked to complete the SUS directly after they have completed the resuscitation scenario
Time frame: 15 minutes
Unified Theory of Acceptance and Use of Technology questionnaire (UTAUT)
The UTAUT consists of eight domains (performance expectancy, effort expectancy, social influence, facilitating conditions, hedonic motivation, price value, habit, and behavioural intention). This measure will be adapted to assess participants' perceived usability, usefulness, and intention to use the augmented reality-aided tool after study completion. Responses are rated on a 7-point likert scale from 1=Strongly disagree to 7=Strongly agree. Participants will be asked to complete the UTAUT directly after they have completed the resuscitation scenario
Time frame: 15 minutes
State-Trait Anxiety Inventory (STAI) form Y-1
This questionnaire is composed of 20-item self-report subscales to measure the temporary state of anxiety at the time of reporting (STAI form Y-1), which can be affected by stressful situations. Each item is answered on a 4-point Likert scale ranging from 1 (not at all) to 4 (very much). After reversing the scores for stress-absent items (ie, items 1, 2, 5, 8, 10, 11, 15, 16, 19, and 20), the total score is calculated by summing up the weighted scores for the 20 items. STAI ranges from 20 to 80, with higher scores being positively correlated with greater stress. The range of possible scores range from a minimum score of 20 to a maximum score of 80. STAI scores are commonly classified as "no or low anxiety" (20-37), "moderate anxiety" (38-44), and "high anxiety" (45-80). Participants will be asked to complete the STAI directly after they have completed the resuscitation scenario
Time frame: 15 minutes
Visual attention patterns of team leader and medication nurse on augmented reality and resuscitation room elements
Duration and number of visual fixations on pre-defined area of interest (AOI) for the team leader and medication nurse, as captured by the augmented reality device (Microsoft Hololens2). AOIs will include the holograms projected within each augmented reality device, as well as the LCD screen within the resuscitation room and manikin for the team leader.
Time frame: 20 minutes
Team Emergency Assessment Measure (TEAM) survey
The TEAM survey is a validated tool designed to assess team performance during emergency scenarios, focusing on non-technical skills. It consists of 11 items rated on a 5-point Likert scale (0 \[Never/Hardly ever\] to 4 \[Always/Nearly always\]) across three domains: Leadership, Teamwork, and Task Management, with an additional overall performance rating. Scores range from 0 (poor performance) to 44 (excellent performance), providing a comprehensive measure of team dynamics, communication, and coordination. Participants will complete the TEAM survey immediately after each resuscitation scenario to evaluate the team's effectiveness in managing the simulated IHCA
Time frame: 10 minutes
Concise Assessment of Leader Management (CALM) Survey
The CALM survey is a validated tool for assessing leadership in acute resuscitation scenarios, focusing on the Team Leader's performance. It includes 15 four-point Likert scale items (rarely, sometimes, mostly, always) across 4 domains-Leadership (role and style, 2 items), Communication (clarity and closed-loop reinforcement, 2 items), Team Management (role assignment, task direction, workload balance, team engagement, and case summarization, 5 items), and Medical Management (task prioritization, global awareness, patient reassessment, care planning, and help-seeking, 5 items)-plus 1 dichotomous behavioral item (yes/no on role announcement) and 1 global rating item comparing the leader to peers (below expected, as expected, above expected, top 5%). Scores for the Likert items range from 15 (poor leadership) to 60 (outstanding leadership), with additional binary and comparative assessments. Team members will complete the CALM survey immediately after each resuscitation scenario.
Time frame: 10
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.