The goal of this clinical trial is to evaluate feasibility, safety, and performance of the SATURN TS TMVR System for the treatment of moderate-to-severe or severe, symptomatic mitral regurgitation through a transcatheter approach. The main questions it aims to answer are: * is the use of the device feasible? * is it safe (defined as freedom from device-related major adverse events at 30 days)? * does it perform (defined as reduction of MR Grade to ≤ 1+ at 30 days)? Participants will need to do the following as part of the clinical trial: * complete 6-Minute Walking Test * complete Quality of Life Questionnaires * undergo blood evaluations * CT scan * 12 lead ECG * Transesophageal Echocardiography * Transthoracic Echocardiogram * the study procedure (valve implantation, right heart catheterization, left arterial pressure, fluoroscopy/ angiogram)
The SATURN Trans-Septal Transcatheter Mitral Valve Replacement System (SATURN TS System) is intended for use in adult patients suffering from heart failure symptoms (NYHA class II or greater) with moderate to severe or severe mitral regurgitation (MR ≥3+) who are deemed to be at high risk for open-heart mitral valve surgery by a multidisciplinary Heart Team including at least a cardiac surgeon and a cardiologist, experienced in the care of patients with mitral valve disease. CASSINI-EU is a single-arm, prospective, multicenter pilot trial. The purpose of the study is to evaluate feasibility, safety, and performance of the SATURN TS TMVR System for the treatment of moderate-to-severe or severe, symptomatic mitral regurgitation through a transcatheter approach. Primary objectives are to evaluate the feasibility, safety and performance of the SATURN TS TMVR System at 30 days. Secondary objectives and additional outcomes are long term safety and performance of the SATURN TS TMVR System. Up to 30 patients will be treated at up to 6 qualified investigational sites in Europe.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
TREATMENT
Masking
NONE
Enrollment
30
The SATURN TS TMVR System will be implanted through a transcatheter approach in patients with symptomatic mitral regurgitation.
Tbilisi Heart and Vascular Clinic
Tbilisi, Georgia
RECRUITINGVilnius University Hospital Santaros Klinikos
Vilnius, Lithuania
RECRUITINGWarsaw Medical University
Warsaw, Poland
RECRUITINGSafety Endpoint - Freedom from Device Related Major Adverse Events
Freedom from device-related major adverse events
Time frame: 30 days post-procedure
Technical Procedural Success Endpoint
Technical success defined as alive patient at exit from procedure room with all the following: * Successful access, delivery of the SATURN TS Bioprosthesis, and retrieval of the TS Delivery Systems * Correct positioning of the first intended SATURN TS Bioprosthesis * Freedom from emergency surgery or mitral valve re-intervention related to the device or access procedure
Time frame: Procedure
Efficacy Endpoint - Reduction of Mitral Regurgitation Grade to ≤ 1+
Reduction of MR Grade to ≤ 1+
Time frame: 30 days post-procedure
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.