Fluid administration is a commonly performed in the ICU for critically ill patients. However, it can lead to complications such as fluid overload, pulmonary edema, and increased mortality in some patients. Therefore, identifying patients who are likely to respond to fluid therapy is crucial for optimizing their management. Several methods have been used to assess fluid responsiveness, such as passive leg raising, stroke volume variation, and cardiac output monitoring. However, these methods have limitations and may not be feasible in all patients. In this study, the investigators aim to evaluate the use of velocity time integral (VTI) and Trendelenburg positioning in predicting fluid responsiveness in ICU patients.
The investigators will perform an echocardiogram both in the supine and Trendelenburg positions for research purposes prior to the ICU team assessing fluid responsiveness (see paragraph below). Critically ill patients in which fluid responsiveness is unclear typically admitted to the ICU routinely undergo a bedside echocardiogram in the supine position and then another echocardiogram still in the supine position after receiving IV fluids to assess the patient's fluid responsiveness (i.e., whether giving a small IV fluid bolus increases cardiac output). VTI is an echocardiographic surrogate for cardiac output and is routinely used in the ICU setting in addition to providing additional information on whether a patient is fluid responsive. This method is already standard practice in the medical and surgical ICU in our PCCM department. Unfortunately, administering IV fluids can potentially cause adverse events such as pulmonary edema, heart failure, interstitial edema, respiratory failure, and death. The use of a method, such as the passive leg raise maneuver (i.e., raising patient's legs by 30 degrees for 1 minute and then evaluating hemodynamic measurements), help predict whether a patient would benefit from IV fluids prior to giving them fluids in order to prevent these aforementioned adverse events since it is a reversible process. Literature and current practice support the use of the passive leg raise (PLR) maneuver in predicting fluid responsiveness, where an increase of at least 15% signifies a positive fluid response. Similar to IV fluids, the PLR maneuver can cause adverse events, is cumbersome, and not feasible in certain circumstances. There is recent research which suggests that Trendelenburg positioning (TP) can be used as an alternative approach that is potentially safer and less cumbersome. This study aims to evaluate a cutoff increase in VTI that would be accurate in predicting fluid responsiveness in patients undergoing TP. As stated above, in our study we will see if placing the patient in TP (i.e., tilt head of the bed 15 degrees downward) will predict if the patient is fluid responsive. The investigators want use ROC analysis to determine the cutoff VTI increase and the accuracy of using TP in predicting fluid responsiveness. The gold standard is to check VTI prior to and after administering an IV fluid bolus and the current literature demonstrates that a VTI increase by 15% is indicative of an appropriate fluid response. The patients in the study in the ICU will receive IV fluids regardless of our study based on the clinician's discretion (i.e., our study will not affect the decision of the clinician in any way). The bedside echocardiogram takes less than 2 minutes to perform and will not delay care.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
DIAGNOSTIC
Masking
NONE
Enrollment
400
There are essentially two arms, whereby the patients is being compared to themselves. The "intervention arm" is the same patient undergoing TP from the baseline supine position to determine the change in VTI after subjecting to TP. We will be using a Sonosite PX ultrasound system, which is intended for diagnostic ultrasound imaging or fluid flow analysis of the human body and, more specifically, for our echocardiographic measurements of velocity time integral (VTI; surrogate for stroke volume and cardiac output). The Sonosite PX is a general-purpose ultrasound system intended for use by qualified physicians and healthcare professionals, for evaluation by ultrasound imaging or fluid flow analysis of the human body. This is an FDA-cleared (510K# K200964) commercial device legally marketed in the United States that is being used in accordance with labeling.
Lenox Hill Hospital- Northwell Health
New York, New York, United States
RECRUITINGChange in VTI cutoff in TP that predicts fluid responsiveness
The objective of this study is to determine the change in VTI cutoff with Trendelenburg positioning that would predict fluid responsiveness in medical and surgical intensive care unit patients.
Time frame: ~1 year
Determine if patient factors are independently associated with fluid responsiveness
Evaluate other patient factors (e.g., demographics) to determine if they are independently associated with fluid responsiveness.
Time frame: ~1 year
Association of Trendelenburg positioning on the effect on hemodynamic parameters
Evaluate the effect of Trendelenburg positioning (TP) and fluid challenge (FC) on hemodynamic parameter of blood pressure (i.e., if there is a statistically significant change in the hemodynamic parameter after TP or FC).
Time frame: ~1 year
Association of Trendelenburg positioning on the effect on hemodynamic parameters
Evaluate the effect of Trendelenburg positioning (TP) and fluid challenge (FC) on hemodynamic parameter of heart rate (i.e., if there is a statistically significant change in the hemodynamic parameter after TP or FC).
Time frame: ~1 year
Association of Trendelenburg positioning on the effect on hemodynamic parameters
Evaluate the effect of Trendelenburg positioning (TP) and fluid challenge (FC) on hemodynamic parameter of pulse pressure (i.e., if there is a statistically significant change in the hemodynamic parameter after TP or FC).
Time frame: ~1 year
Association of Trendelenburg positioning on the effect on hemodynamic parameters
Evaluate the effect of Trendelenburg positioning (TP) and fluid challenge (FC) on hemodynamic parameter of central venous pressure (i.e., if there is a statistically significant change in the hemodynamic parameter after TP or FC).
Time frame: ~1 year
Evaluate the predictive accuracy of the change in VTI versus other hemodynamic parameters
Use receiver operating characteristic (ROC) curves to compare the predictive accuracy of the change in VTI compared to the change of certain hemodynamic parameters (e.g., pulse pressure, systolic blood pressure, diastolic blood pressure) with Trendelenburg positioning.
Time frame: ~1 year