The aim of this study is to evaluate whether Trendelenburg maneuver can be used to predict fluid responsiveness in high-risk surgical patients in intensive care unit as compared to Passive Leg Raising test.
Passive Leg Raising test is a well validated dynamic method to predict fluid responsiveness with many advantages as it doesn't use fluid loading, its effect is reversible, and it doesn't rely on heart-lung interaction. However, it has many limitations as (has false negative effect in patients with intra-abdominal hypertension), also, it may not be suitable in some surgical patients. Trendelenburg maneuver (TM) is often used to treat hemodynamic unstable patients when hypovolemia is suspected, through a mechanism similar to Passive Leg Raising test Yonis, et al reports that change in cardiac output during Trendelenburg maneuver is a reliable predictor of fluid responsiveness in patients with acute respiratory distress syndrome in prone position under protective ventilation. Another study reports that change in velocity time integral during trendelenburg maneuver predicts fluid responsiveness in cardiac surgical patients in operating rooms
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
DIAGNOSTIC
Masking
SINGLE
Enrollment
60
The investigator will measure changes in velocity time integral (VTI) and stroke volume (SV) during Trendelenburg maneuver (TM) in high-risk surgical patients by trans-thoracic Doppler echo cardiography.
The investigator will measure changes in velocity time integral (VTI) and stroke volume (SV) during Passive leg raising (PLR) test in high-risk surgical patients by trans-thoracic Doppler echo cardiography.
Tanta University Hospitals
Tanta, El-Gharbia, Egypt
The validity of Trendelenburg maneuver
Measurement of the validity of Trendelenburg maneuver to predict fluid responsiveness by measuring the percentage change in velocity time integral (VTI) by Doppler echocardiography in high risk-surgical patients.
Time frame: At the end of Trendelenburg maneuver within 1 minute
Correlation between the accuracy of the percentage change in velocity time integral (VTI) during Trendelenburg maneuver and passive leg raising test (PLR) test
Correlation between the accuracy of the percentage change in velocity time integral (VTI)during Trendelenburg maneuver and passive leg raising test will be measured.
Time frame: At the end of Trendelenburg maneuver and passive leg raising test within 1 minute