This is a pre-market, first-in-human, pilot, interventional, clinical investigation that aims to evaluate safety and feasibility of the FieldForce™ Ablation system in patients with atrial fibrillation who are indicated for an AF catheter ablation.
Atrial fibrillation (AF) is a cardiac rhythm disorder characterized by irregular and often abnormally fast contractions of the atrial cardiomyocytes resulting in various symptoms, including palpitations, dizziness, shortness of breath and tiredness. AF is the most common sustained cardiac arrhythmia, having a prevalence of about ≈2% in the general population. AF can be associated with increased morbidity and mortality in patients with cardiovascular disease, and increased risk of stroke in general population. Catheter ablation for the treatment of AF is primarily performed with radiofrequency (RF) or cryoballoon (CB) catheters to achieve anatomic pulmonary vein isolation (PVI). However, the technical challenges of achieving effective PVI and recognized risks of complications are two most important factors driving the need for replacing thermal ablation technologies like RF and CB. Pulsed field ablation (PFA) is a non-thermal ablation technology which uses high voltage pulsed electrical fields to ablate tissues. This destabilizes cell membranes by forming irreversible nanoscale pores and leakage of cell contents, culminating in cell death. Several clinical studies have demonstrated that PFA can achieve pulmonary vein isolation with minimal collateral damage in a time-efficient manner. The FieldForce™ Ablation System utilizes PFA with an innovative electrode technology called FieldBending™ designed to improve safety, tolerability, and efficacy for focal deflectable catheters used for the treatment of AF.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
TREATMENT
Masking
NONE
Enrollment
40
The FieldForce Ablation System is indicated for cardiac electrophysiologic mapping, delivery of diagnostic pacing stimuli, and pulse field ablation of cardiac tissue. When used with the FieldForce Ablation Catheter, the FieldForce System is intended to be used in the right/left atria and/or left/right ventricle to deliver PFA ablation lesions in the selected areas of the chamber.
Na Homolce Hospital
Prague, Czechia
RECRUITINGIncidence of early and late onset adverse events
Adverse events to evaluate the safety of the FieldForce™ Ablation System will be collected. The incidence of the major safety events will be evaluated.
Time frame: 30 days and 12 months
Performance
To characterize the proportion of subjects who achieved pulmonary vein isolation (PVI) using the FieldForce™ Ablation System
Time frame: index procedure and 3 months
Device or Procedure Related SAEs
Proportion of subjects reporting one or more device-or procedure-related SAEs.
Time frame: 30 days, 3 months, 6 months and 12 months
Presence of Atrial Arrhythmias from index procedure through end of study
To evaluate freedom from atrial arrhythmia (including atrial fibrillation, flutter, or tachycardia).
Time frame: 6 months and 12 months
Procedure Time
To characterize procedure times (including total duration, transpired ablation time, fluoroscopy time).
Time frame: Index procedure