Clinical Trial Phase IV Indication: Moderate-severe obstructive sleep apnea and dyslipidemia. Objectives: Main objective: To test whether 12 months of CPAP treatment associated with conventional pharmacological treatment improves the lipid profile of patients with dyslipidemia and moderate to severe OSA. Secondary objectives: * To test whether 12 months of treatment with CPAP associated with conventional pharmacological treatment improves serum uric acid concentration in patients with dyslipidemia and moderate-severe OSA. * To determine the additional medium- and long-term effect of CPAP on insulin resistance in patients with dyslipidemia and moderate-severe OSA. * To evaluate the impact of CPAP treatment on cardiovascular risk reduction in patients with dyslipidemia and moderate-severe OSA. * To analyze the impact of supplemental CPAP treatment on glycemic control and C-reactive protein concentration in patients with dyslipidemia and moderate-severe OSA. * To establish the impact of supplemental CPAP therapy on health-related quality of life in patients with dyslipidemia and moderate-severe OSA. * To evaluate the effect of CPAP on inflammatory cytokines, oxidative stress biomarkers, sympathetic tone and intake-regulating hormones in patients with dyslipidemia and moderate-severe OSA. * To relate CPAP-induced changes in serum lipid and uric acid concentration to changes in basal inflammatory response, oxidative stress, sympathetic activity, and intake-regulating hormones. * To identify the subgroup of patients with dyslipidemia and moderate-severe OSA in whom 12 months of CPAP treatment achieves a more marked reduction in serum lipids and uric acid. Design Randomized, parallel-group, nonblinded, controlled clinical trial with conventional treatment. Study population Subjects aged 35 to 80 years with a diagnosis of dyslipidemia made at least six months ago and with moderate-severe obstructive sleep apnea (OSA) not requiring CPAP treatment according to conventional indications. Sample size: 110 patients in each treatment arm. Treatment Patients will be randomly assigned in a 1:1 ratio to one of the following treatment arms: 1. Conventional hygienic-dietary recommendations and promotion of daily physical activity. 2. Conventional hygienic-dietary recommendations and promotion of daily physical activity, plus treatment with positive airway pressure (CPAP). Efficiency variables * Main variables: LDL-cholesterol and uric acid. * Total cholesterol, HDL-cholesterol and triglycerides. * Basal blood glucose, glycosylated hemoglobin (HbA1c), creatinine and C-reactive protein. * Systemic biomarkers: inflammatory (IL-6, IL-8 and TNF-α), oxidative stress (8-isoprostane), endothelial damage (endothelin, VCAM-1 and ICAM-1), sympathetic activity (neuropeptide Y) and appetite-regulating hormones (leptin, orexin A/hypocretin 1 and ghrelin). * Clinical questionnaires: SF-12, EuroQoL, FOSQ and IPAQ. Safety variables * Clinical adverse event reporting. * CPAP compliance (average hours of use per day). * Epworth Sleepiness Questionnaire. * Development of cardiovascular events.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Enrollment
220
Treatment will start with an empirical pressure of 8 cmH2O and, within a maximum of 3 weeks, the pressure will be adjusted by means of automatic titration, establishing the pressure corresponding to the 95th percentile.
Hygienic-dietary recommendations on sleep and intervention for the promotion of daily physical activity, establishing walking as a goal 10,000 steps per day. To do this, they will be provided with a pedometer and asked to fill out a form with the steps walked each day. At each visit, the distance walked will be reviewed and the goal set will be reiterated.
Hospital Universitario del Henares
Coslada, Madrid, Spain
RECRUITINGCPAP effect on lipid profile
Comparison of 12-months change from baseline in the plasma level of LDL-cholesterol between the two study groups
Time frame: 12 months
CPAP effect on lipid profile-2
Comparison of 12-months change from baseline in the plasma level of HDL-cholesterol between the two study groups
Time frame: 12 months
CPAP effect on lipid profile-3
Comparison of 12-months change from baseline in the plasma level of total cholesterol between the two study groups
Time frame: 12 months
CPAP effect on lipid profile-4
Comparison of 12-months change from baseline in the plasma level of triglycerides between the two study groups
Time frame: 12 months
CPAP effect on uric acid
Comparison of 12-months change from baseline in the plasma level of uric acid between the two study groups
Time frame: 12 months
Medium-term CPAP effect on insulin resistance
Comparison of 6-months change from baseline in the HOMA index between the two study groups
Time frame: 6 months
Long-term CPAP effect on insulin resistance
Comparison of 12-months change from baseline in the HOMA index between the two study groups
Time frame: 12 months
CPAP effect on cardiovascular risk
Comparison of 12-months change from baseline in the cardiovascular risk score between the two study groups
Time frame: 12 months
CPAP effect on glycemic control
Comparison of 12-months change from baseline in the plasma level of HbA1c between the two study groups
Time frame: 12 months
CPAP effect on C-reactive protein
Comparison of 12-months change from baseline in the plasma level of C-reactive protein between the two study groups
Time frame: 12 months
CPAP effect on sleepiness
Comparison of 12-months change from baseline in the Epworth sleepiness scale between the two study groups
Time frame: 12 months
CPAP effect on health-related quality of life
Comparison of 12-months change from baseline in the EuroQoL score between the two study groups
Time frame: 12 months
CPAP effect on health-related quality of life-2
Comparison of 12-months change from baseline in the SF-12 score between the two study groups
Time frame: 12 months
CPAP effect on daily physical activity
Comparison of 12-months change from baseline in the iPAQ score between the two study groups
Time frame: 12 months
CPAP effect on inflammatory cytokines
Comparison of 12-months change from baseline in the plasma levels of IL-6, IL-8 and TNF-α between the two study groups
Time frame: 12 months
CPAP effect on oxidative stress biomarkers
Comparison of 12-months change from baseline in the plasma level of 8-isoprostane between the two study groups
Time frame: 12 months
CPAP effect on sympathetic tone
Comparison of 12-months change from baseline in the plasma level of neuropeptide Y between the two study groups
Time frame: 12 months
CPAP effect on intake-regulating hormones
Comparison of 12-months change from baseline in the plasma levels of leptin, orexin A/hypocretin 1 and ghrelin between the two study groups
Time frame: 12 months
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.