Respiratory failure has historically been one of the most important causes for admittance of patients to the critical care unit. This problem was the most important reason during the COVID-19 pandemic. Following the evolution of the physiology of the lung has therefore been the number one concern during these challenging times in the intensive care unit (ICU). Respiratory oscillometry (RO) identifies the lung impedance by applying small pressure oscillations onto the breathing or ventilation. Information about the respiratory mechanics can be extracted out of this impedance, including the resistance (R) and compliance (C) of the lung. The VUB developed a robust, patient safe RO measurement protocol that delivers high quality measurements with the least possible interference with the patient's breathing/ventilation. The technique challenges current state-of-the-art techniques also aiming at identifying R and C of the respiratory system (not exclusively RO). The RO measurement protocol is in line with the technical standards of the ERS (European Respiratory Society) and has been successfully and safely tested on emulators and some parts on test subjects. The clinical investigation aims at a powered equivalence investigation between the RO measurement protocol and a standard of care dynamic compliance estimate on invasive ventilated patients. As secondary objectives, the feasibility of the RO techniques will be investigated during pressure support ventilation and the RO estimates will also be compared with other accepted respiratory mechanics estimation tools. To enable the investigation, a RO algorithm is developed, and a RO measurement extension is implemented in the DemcAir® ventilation system of Demcon. This was a fully tested ventilator that received a CE mark under the previous MDD regulation. However, Demcon, which produces ventilator parts for other commercial partners, removed the label to avoid competition with their partners. The ventilator will only execute the protocol on demand and save the data on an USB stick available in the ventilator. At any time, the RO measurement procedure can be stopped, and the ventilator will return to its initial ventilation. The USB stick is used to transport the data to a separate (VUB) laptop where the data processing is done.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
DIAGNOSTIC
Masking
QUADRUPLE
Enrollment
21
compliance can be measured by analyzing pressure volume curves generated through different methods
Universitair Ziekenhuis Brussel
Jette, Brussel Hoofstedelijk Gewest, Belgium
RECRUITINGcompliance
compliance of the lung expressed in "ml/cmH20 "
Time frame: Twice a day with at least 4hour interval, during 1 hour, compliance will be measured in every interventional action: ROELEC protocol, SOTA, dynamic P/V curve and low flow P/V curve
resistance
resistance of the lung expressed in cmH20/L/sec
Time frame: Twice a day with at least 4hour interval, during 1 hour, resistance will be measured in every interventional action: ROELEC protocol, SOTA, dynamic P/V curve and low flow P/V curve
impedance
lung impedance expressed in Ohm
Time frame: Twice a day with at least 4hour interval, during 1 hour, impedance will be measured in every interventional action: ROELEC protocol, SOTA, dynamic P/V curve and low flow P/V curve