The objective of the study ist to compare the Dilapan-S and the Cook Ballon device for the mechanical induction of labour in women with a previous C-section. There is currently lack of data regarding this comparison of the two methods for mechanical labour induction in this patient collective. Any method used for labour induction is therefore off-label. The primary outcome is the time between placement of the device and delivery. Ad secondary outcomes are among others the cesarean delivery rate and patient satisfaction with the induction method.
The cesarean section (CS) rate is increasing worldwide, with previous CS being an important factor contributing to this trend. The investigators think that VBAC may be safe, provided a careful selection of the patients is performed. The individual birth management is particularly important if labour has to be induced, as in case of approximately 25% of women attempting VBAC. Counselling patients about labour induction can be challenging, as they should be offered not only a safe, but also an effective method. Labor induction can be achieved by using several approaches: administration of drugs, which induce uterine contractions, such as prostaglandins or oxytocin, performing an amniotomy, or using mechanical methods. In Switzerland and implicitly in the investigators' institution, PGE after CS are rarely employed in carefully selected cases. Oxytocin administration after performing amniotomy is considered to be a safe method, but may be less effective with an unfavorable BISHOP score (\<6). An possible alternative in case of unripe cervix is induction of labour by use of mechanical methods: balloon catheters and laminaria stents. The investigators currently use the double balloon catheter device (Cook Inc) for this purpose. This device is inserted transcervically and both ballons are inflated with sterile 0.9% saline solution. The catheter remains in place until spontaneously expelled or until start of active labour. If neither happens, it will be removed after 12 hours, followed by oxytocin administration and amniotomy. Recently, an alternative method for mechanical induction is gaining increased attention: the use of hygroscopic cervical dilators. The method seems to be equally effective and safe as directly compared to a single device catheter in a low risk population of women without uterine scar. When used in patients with previous cesarean section, the rate of spontaneous labour seems to resemble existent data for induction with balloon catheter, this including the investigators' collective. One of the advantages of Dilapan-S® could be the lack of vaginal protrusion and the fact that it does not have to be fixated under tension. Women seem to feel more mobile with Dilapan®, the perception of relaxation moments between contractions as well as sleep periods during the induction seem to be improved with Dilapan®.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
OTHER
Masking
NONE
Enrollment
137
Cook double balloon will be introduced transcervically. The double balloon will be inflated with sterile 0-9% saline solution (maximum 80 ml in each balloon of the double device), then the catheter will be fixed with a tape at the women's thigh without traction. The catheter will remain in place until spontaneously expelled or start of active labour. If neither happens, the device will be removed after 12-24 hours and oxytocin will be administered and amniotomy as soon as feasible. If the cervix remains unfavorable after two cycles of 6 hours of oxytocin infusion, the induction will be classified as unsuccessful and C-section will be performed.
A maximum number of 5 hygroscopic cervical dilator rods will be inserted transcervically, after humidification with sterile 0.9% saline solution. They will be fixed in this position by inserting a humidified compress into the vagina. They will remain in place until spontaneously expelled or until start of active labour. In neither happens, the devices will be removed after 12-24 hours and oxytocin will be administered and amniotomy as soon as feasible. If the cervix remains unfavorable after two cycles of 6 hours of oxytocin infusion, the induction will be classified as unsuccessful and C-section will be performed.
University Hospital of Obstetrics and Gynäkologie, Inselspital
Bern, Switzerland
RECRUITINGInduction-to-delivery interval (IDI) after induction of labour (COOK catheter or Dilapan) in women with previous CS.
The time between placement of the device and delivery
Time frame: 72 hours
Cesarean delivery rate
How many women will get at the end a C-section after inducing the labour
Time frame: 72 hours
Neonatal outcomes
The cord arterial pH (\< 7.10)
Time frame: 2 hours
Neonatal outcomes
5 minutes APGAR-Score (\< 7)
Time frame: 2 hours
Neonatal outcomes
Transfer to the ICU
Time frame: 2 hours
Maternal infection rate
To asses the maternal infection status the investigators use the temperature (fever \>38.0°), Leucocytosis (\> 16.000 G/l), CRP (\> 50)
Time frame: 96 hours
Patient satisfaction
All participant will receive a questionnaire after birth regarding the time from induction initiation until active phase of labour, covering questions such as convenience of the induction method (multiplicity of vaginal manipulation, comfort and pain experience)
Time frame: 96 hours
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.