The goal of the study was to estimate the outcome (mortality and morbidity) among hemodynamically unstable neonates, as well as the time to return to hemodynamic stability following the use of ECHO in the management of hemodynamically unstable neonates.
-All patients will be subjected to : Full clinical examination for manifestation or signs of hemodynamic instability and daily thereafter until discharge. An echocardiographic assessment using Vivid T8 Pro ( GE MEDICAL SYSTEMS ( CHINA ) CO, LTD.) is done if manifestations of hemodynamic instability or shock appeared. The imaging planes were identified by transducer location (subxiphoid, apical, parasternal, suprasternal notch, and right parasternal). The segmental approach was used to describe all of the major cardiovascular structures in sequence. Suggested plan of management will be as the following: 1. Neonates with low LVO and impaired left ventricular contractility: dobutamine at a dose of 5-20 μg/kg/min was given, and if no improvement, volume expansion as a single intravenous infusion of 10-20 ml/kg of the crystalloid solution was given. If still no improvement, hydrocortisone at a dose of 1 mg/kg every 4 h was added. If improvement was not achieved, epinephrine was added at a dose of 0.05-2.6 μg/kg/min \[11\]. 2. Neonates with LVO and hypovolemia (under-filled left ventricle): volume expansion as a single intravenous infusion of 10-20 ml/kg of the crystalloid solution will be given. If still no improvement, it was repeated \[11\]. 3. Neonates with normal or high LVO without PDA: dopamine at a dose of 5-20 μg/kg/min is given. If no improvement, hydrocortisone at a dose of 1 mg/kg every 4 h is added. If improvement was not achieved, epinephrine is added at a dose of 0.05-2.6 μg/kg/min \[11\]. 4. Neonates with normal or high LVO and hemodynamically significant PDA: PDA will be treated either medically or surgically \[11\]. 5. During the current study period, all previously mentioned hemodynamically unstable neonate values were compared to values collected from the controlled group (200 hemodynamically stable neonates). 6. Neonates will be monitored regularly and subjected to repeated echocardiographic and clinical examinations to detect clinical and laboratory findings suggestive of hemodynamic instability or shock.
Study Type
OBSERVATIONAL
Enrollment
50
Functional echocardiography assessment
Sohag University Hospital
Sohag, Egypt
RECRUITINGFunctional echocardiography ( ejection fraction using M mode echocardiography)
Time frame: Repeat echocardiographic assessment on a daily basis ( 24 hours interval)
Functional echocardiography fraction shortening by M mode echocardiography
Time frame: Repeat echocardiographic assessment on a daily basis ( 24 hours interval)
Assessment of ductus arteriosus ( diameter, shunt directionality ) by 2D and color doppler echocardiography
Time frame: Repeat echocardiographic assessment 5 days after the first echo assessment
Assessment of pulmonary hypertension
Using peak tricuspid regurgitation velocity by colour doppler
Time frame: Repeat echocardiographic assessment on a daily basis ( 24 hours interval) following proposed treatment of pulmonary hypertension
Assessment of LV cardiac index
Assessment of LV outflow tract diameter by 2D/M mode echocardiography in parasternal long axis view and assessment of Velocity-time integral of PW in LV outflow tract by PW doppler in apical five-chamber view
Time frame: Repeat echocardiographic assessment on a daily basis ( 24 hours interval)
Assessment of RV cardiac index
Assessment of RV outflow tract diameter by 2D echocardiography and Velocity-time integral of PW in RV outflow tract
Time frame: Repeat echocardiographic assessment on a daily basis ( 24 hours interval)
Assessment of SVC flow
Assessment of SVC diameter (mean of systolic and diastolic diameter) by M mode echocardiography in high parasternal view
Time frame: Repeat echocardiographic assessment on a daily basis ( 24 hours interval)
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Assessment of RV function
Measurement of Tricuspid annular plane systolic excursion (TAPSE) using M mode echocardiography in apical four chamber view
Time frame: Repeat echocardiographic assessment on a daily basis ( 24 hours interval)