The aim of this clinical trial is to investigate the efficacy of wet cupping therapy (WCT) on cerebral oxygenation using the NIRS device. With the demonstration of the positive effect of the WCT on cerebral oxygenation, it was aimed to use it effectively in stroke rehabilitation. In the outpatient clinic setting, firstly the sensor pads of the NIRS device will be attached to the arcus superciliaris (GB14) under the tuber frontalis on both sides. After the measurement is initiated, WCT will be applied to the planum occipitale (DU 20) and to the pars squamosa (GB6-8) of the temporal bone on the sides. Measurement will continue for 10 minutes during and after the WCT application. NIRS and oxygenation measurement data will be compared before, during, and after the WCT application.
The importance of NIRS is that it can detect differences in tissue oxygen uptake that cannot be routinely identified by existing methods (24). The ability of near-infrared (NIR; near infrared; wavelength 650 - 1100nm) light to penetrate tissues and to be absorbed by some chromophores (such as haemoglobin, cytochrome oxidase, bilirubin, urobilin) has formed the basis of regional cerebral oxygen saturation (rScO2) measurement (15). NIRS is a technique in which the amount of absorption of NIR light by chromophore molecules \[such as oxyhaemoglobin (O2Hb) and deoxyhaemoglobin (HHb), cytochrome-c oxidase (CCO), myoglobin\] is measured while passing through tissues (16). rScO2 values less than 40% or changes greater than 25% from baseline values may be a harbinger of cerebral ischaemia (17). Cerebral oximetry has attracted attention because it is easy to use and uncomplicated. NIRS should be used as a trend monitor. In the current study, it is aimed to investigate the efficacy of wet cupping therapy (WCT) on cerebral oxygenation using the NIRS device. Following the enrollment of the healthy individuals, they will all receive one session of WCT. During the WCT application, the cerebral oxygenation levels will be measured with an NIRS device. In the outpatient clinic setting, the NIRS device's sensor pads will be attached to the arcus superciliaris (GB14) under the tuber frontalis on both sides. After the measurement is initiated, WCT will be applied to the planum occipitale (DU 20) and the pars squamosa (GB6-8) of the temporal bone on the sides. Measurement will continue for 10 minutes during and after the WCT application. The data obtained by NIRS will be compared before, during, and after the WCT application so that we will be able to find out any possible effects of WCT on cerebral oxygenation.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
PREVENTION
Masking
NONE
Enrollment
40
The cupping (WCT) procedure consists of five phases: Primary suction: Using a manual suction pump, air was drawn from glass cups that were positioned on the chosen locations. The skin and subcutaneous tissue swelled as a result of the cups' five minutes of skin contact. Area disinfection: After disinfecting the cupped areas with povidone-iodine, they were wiped with sterile gauze. Scarification: Using a sterile number 11 surgical blade, superficial incisions measuring 20-30 gauge in length and 1-2 mm in depth were made on the skin. Bloodletting and secondary suction: Once again applied to the scarified areas, the previously removed cups created suction using the manual pump which was previously mentioned. In order to fill the cups, blood was drawn from the skin's and subcutaneous tissue's capillaries. Removing and dressing: After 10 minutes, the cups filled with blood were removed. The application areas were wiped with sterile gauze, and dressings were applied.
Kayseri City Hospital
Kayseri, Turkey (Türkiye)
RECRUITINGOxygen levels
Cerebral oxygenation levels measured by NIRS device
Time frame: Just before WCT application and 10 minutes after the application