This study aims to compare between High tone power therapy (modulated frequency current) and Transcutaneous electrical nerve stimulation (fixed frequency current) on spasticity and selected kinematic gait parameters in stroke patients.
Stroke is a neurological deficit attributed to an acute focal injury of the central nervous system (CNS) by a vascular cause . Stroke is one of the leading causes of disability and mortality in the globe, stroke occurs when blood flow to the brain is restricted due to a blocked or ruptured artery; the cerebral energy supply is interrupted, resulting in tissue destruction and widespread neuronal, cognitive impairments, and psychological morbidity . Stroke is the second major cause of death and disability worldwide with over 13 million new cases annually . Stroke has been described as a major source of both mortality and global disability . Approximately 795,000 people experience stroke annually, and 60% (or 465,000) of them need rehabilitation . Spasticity is a symptom of stroke, brain and spinal cord damage, multiple sclerosis, cerebral palsy, and other neurological illnesses that cause paralysis . The most common spastic pattern in the lower limbs is adduction and extension of the knee with an Equinovarus foot . This impacts gait patterns and daily functioning activities . Treatment modalities for the management of spasticity include Stretching, splinting, Neuromuscular electrical stimulation (NMES), extracorporeal shock wave therapy, transcranial and spinal cord magnetic stimulation, Surgical treatment, neurectomy, rhizotomy, and myelotomy; also, many drugs used for treating spasticity oral drugs like Baclofen, Tizanidine, and injectable medications like Phenol/alcohol and Botulinum 2 toxin . Transcutaneous electrical nerve stimulation (TENS) stimulates large diameter mechano-sensitive nerve fibers in the skin it's a non-invasive treatment that has been reported to affect pain control and sensory stimulation which is commonly used in the treatment of chronic and acute pain with possible mechanisms of action including segmental inhibition, the release of endogenous opioids, counter-irritation, nerve conduction block, increase muscle power and movement function . High-tone power therapy (HTT) is a unique characteristic of electrotherapy. It uses intermediate frequency, metal-compatible alternating current whose frequency oscillates between approximately 4000 Hz and 33000 Hz, and intensity is adjusted, unlike traditional electrotherapies as transcutaneous electrical nerve stimulation (TENS). Its main effects are introducing energy into the body to activate cells, producing an oscillation or vibration in the cells and tissues to promote metabolism, scattering the mediators of pain and inflammation leading to pain relief, and normalizing cell metabolism and nerve regeneration ). The effective management of spasticity continues to pose challenges to physiotherapy management, there appears to be a dearth of adequate information on high tone power therapy in the management of spasticity; There are several physiotherapy approaches for managing spasticity but there is a lack of evidence to show which is most effective . Statement of the problem: This study will answer the following question: Is there any difference between the effect of high-tone power therapy (modulated frequency current) versus transcutaneous electrical nerve stimulation (fixed frequency current) on spasticity and selected kinematic gait parameters in stroke patients?
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Enrollment
51
sessions are applied for 30 minutes, 3 times per week, for 3 months
sessions are applied for 30 minutes, 3 times per week, for 3 months
sessions are applied for 1 hour, 3 times per week, for 3 months in form o fstretching exercise , range of motion exercises , conventional gait training progressive resistance exercises
faculty of physical therapy, Cairo university
Giza, Egypt
Modified Ashworth Scale (MAS)
This scale is used to measure spasticity of Calf muscle in grades from 0 to 5.
Time frame: measurements will be done 3 days before the start of the treatment program and will be done after 3 days post intervention
Computerized electromyography (EMG) using H/M ratio
EMG is an objective device used to measure spasticity of the Soleus muscle in percentage (%)
Time frame: measurements will be done 3 days before the start of the treatment program and will be done after 3 days post intervention
Ten-meter Walk test(10-MWT)
This scale is used to measure walking speed in m/s * self-selected walking speed (SSWS) in (m/s). * fastest walking speed (FWS) in (m/s).
Time frame: measurements will be done 3 days before the start of the treatment program and will be done after 3 days post intervention
Time up and go test (TUG)
This test is used to measure time taken by patient to apply sit to stand, walk a distance of 3 meters, turn and walk back to the chair in (sec.)
Time frame: measurements will be done 3 days before the start of the treatment program and will be done after 3 days post intervention
Gait velocity
Gait Analyzer Smart Phone Application is an objective tool that assesses gait velocity (m/s).
Time frame: measurements will be done 3 days before the start of the treatment program and will be done after 3 days post intervention
cadence
Gait Analyzer Smart Phone Application is an objective tool that assesses cadence: the number of steps per second in (steps/ s).
Time frame: measurements will be done 3 days before the start of the treatment program and will be done after 3 days post intervention
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
step time
Gait Analyzer Smart Phone Application is an objective tool that assesses step time in ( msec.)
Time frame: measurements will be done 3 days before the start of the treatment program and will be done after 3 days post intervention
step time symmetry
Gait Analyzer Smart Phone Application is an objective tool that assesses step time symmetry: the symmetry in time between affected and unaffected lower limbs in percentage (%)
Time frame: measurements will be done 3 days before the start of the treatment program and will be done after 3 days post intervention
step length
Gait Analyzer Smart Phone Application is an objective tool that assesses step length by the inertial sensor system symmetry in meters (m).
Time frame: measurements will be done 3 days before the start of the treatment program and will be done after 3 days post intervention
step length symmetry
Gait Analyzer Smart Phone Application is an objective tool that assesses step length symmetry: the symmetry in step length between affected and unaffected lower limbs in percentage (%)
Time frame: measurements will be done 3 days before the start of the treatment program and will be done after 3 days post intervention
Lafayette Hand-held Dynamometer
This is an objective device used to measure the isometric contraction of dorsi flexors in pounds (lbs.)
Time frame: measurements will be done 3 days before the start of the treatment program and will be done after 3 days post intervention