During the recovery process, the activity of the sympathetic system decreases, while the activity of the parasympathetic system increases. In line with this information, the nervous system can be regulated in a noninvasive and practical way by using transcutaneous auricular vagus nerve stimulation in order to achieve rapid recovery in the athlete after the activity.
In sports where physical loads are high, athletes can usually participate in more than one training or race during the day. Such work increases the athlete's fatigue, affects their performance and can cause serious declines. Therefore, an efficient and effective recovery process after high-intensity work and training that causes a decrease in performance is also very important for the athlete's next performance. With the start of sports activity or exercise, sympathetic activation in the body increases and after a while reaches a plateau value at maximum activity. With the end of exercise, this time the suppressed parasympathetic activity begins to increase and the sympathetic system returns to a resting state over time. There are insufficient studies in the literature investigating the use of Transcutaneous Auricular Vagus Nerve Stimulation on the athletic population. Although it is clear that the application has effects on the sympathetic and parasympathetic nervous systems, more clinical research is needed on athletes. In this study, we aimed to investigate the effects of auricular vagus nerve stimulation (VNS) on vagal activity by examining the effect of transcutaneous auricular vagus nerve stimulation on recovery in amateur athletes through applications such as pulse and SpO2, blood pressure, perceived fatigue, and respiratory function tests.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Enrollment
40
After exercise loading, active ear VSS was applied to Group 1. Application was made simultaneously in both ears, with a 300 microsecond pulse duration, a biphasic asymmetric waveform, and a frequency of 25 Hz, for a total of 20 minutes. All assessments were recorded 3 times: at the beginning of the test, after exercise loading, and after active VSS application.
After the exercise challenge, Group 2 underwent sham VSS. Device parameters were set to the same as Group 1 (300 microsecond pulse duration, biphasic asymmetric waveform, and 25 Hz frequency). Both headphones were worn for a total of 20 minutes. However, the participant heard only the device's power-on tone and received no current. All assessments were recorded three times: at the beginning of the test, after the exercise challenge, and after sham VSS.
İstanbul Gelisim University
Istanbul, Istanbul, Turkey (Türkiye)
Respiratory Function Test
In our study, FVC measurement were calculated using a MiniSpir2 brand spirometer device. The measurements were performed while the participants were sitting in a fixed chair. The measurements were repeated 3 times for each participant and the two highest values read on the device were recorded as an average.
Time frame: 2 Months
Respiratory Function Test
In our study, FEV1/FVC measurement were calculated using a MiniSpir2 brand spirometer device. The measurements were performed while the participants were sitting in a fixed chair. The measurements were repeated 3 times for each participant and the two highest values read on the device were recorded as an average.
Time frame: 2 Months
Respiratory Function Test
In our study, PEF measurement were calculated using a MiniSpir2 brand spirometer device. The measurements were performed while the participants were sitting in a fixed chair. The measurements were repeated 3 times for each participant and the two highest values read on the device were recorded as an average.
Time frame: 2 Months
Respiratory Function Test
In our study, FEV1 measurement were calculated using a MiniSpir2 brand spirometer device. The measurements were performed while the participants were sitting in a fixed chair. The measurements were repeated 3 times for each participant and the two highest values read on the device were recorded as an average.
Time frame: 2 Months
BORG Perceived Fatigue Measurement
The Borg Perceived Fatigue Scale was used to assess the degree of fatigue perceived by the participants. BORG is a scale developed to assess the level of strain experienced by individuals during physical activities. This scale is based on physical measures such as respiratory rate, heart rate, muscle fatigue and sweating perceived by individuals during physical exertion. The scale is scored between 6 and 20. If the participant's perceived muscle fatigue is very mild, a score of 9 is given. Scores between 12 and 14 on BORG indicate that the exertion is moderate. If the individual perceives that they are exerting very much, a score of 19 is given.
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Time frame: 2 Months