The aim of this randomized controlled trial (RCT) is to determine whether early implant loading that shortens the healing period to 6 weeks can be safely and effectively applied to implants with good initial stability in the maxillary anterior region, which undergoes simultaneous guided bone regeneration (GBR), via clinical examination, intraoral scanning, imageological diagnosis, and aesthetic scoring, and to determine the clinical effect of the small intestine submucosa (SIS) biological barrier membrane in such cases involving early loading. This study is expected to provide preliminary guidance on the timing of loading for a single maxillary anterior implant with insufficient bone volume and provide a theoretical basis for the selection of a biological barrier membrane for GBR in such patients.
Patients were randomized into three groups at a 1:1:1 ratio, including the GBR with a Bio-Gide membrane and delayed implant loading (Gide-DL) group, the GBR with a Bio-Gide membrane and early implant loading (Gide-EL) group, and the GBR with an SIS membrane and early implant loading (SIS-EL) group. The allocation sequence was generated through an online tool (www. random.org) and was concealed in sealed envelopes. At 6 weeks after implant and GBR surgery, the implant stability quotient (ISQ) was measured and recorded at the labial, palatal, mesial, and distal locations via the Osstell device in the Gide-EL group and the SIS-EL group. If the ISQ was ≥ 65, definitive restoration (early loading) was performed (if \< 65, the subject was withdrawn from the trial). The digital impressions and occlusal relationships were obtained via intraoral scanning, and the implant-supported crown was designed based on the digital model. Titanium base abutments with angled screw channels (ASCs) and porcelain veneered zirconia (PVZ) crowns were used for restoration. Immediately after definitive restoration, intraoral scanning was used to record the soft tissue contour at the implant site, and CBCT was used to examine the bone tissue around the implant. In addition, patients in the Gide-DL group underwent definitive restoration at 6 months after surgery (delayed loading), and the treatment process was the same as that in the Gide-EL and SIS-EL groups at 6 weeks after surgery. Clinical examination, intraoral scanning, imageological diagnosis, and aesthetic scoring were used to determine the clinical effect of SIS membranes and early implant loading at 1-year follow-up.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Enrollment
36
Patients underwent definitive restoration at 6 weeks after implant surgery (early loading).
Patients underwent definitive restoration at 6 months after implant surgery (delayed loading).
An small intestine submucosa (SIS) membrane was used in the guided bone regeneration (GBR) surgery.
An Bio-Gide membrane was used in the guided bone regeneration (GBR) surgery.
Beijing Stomatological Hospital, Capital Medical University
Beijing, China
Soft tissue contour assessment
Intraoral scanning was used to collect the soft tissue contour at the implant site, the contour of the implant-supported crown and adjacent natural teeth. The preoperative, immediate postoperative, and 1-year follow-up intraoral scanning data in stereolithography (STL) formats were imported into Exocad 3.0 software. The best-fit images of the median sagittal section at the implant site were extracted, and the horizontal contour changes (HCCs) were measured at 1 mm and 3 mm below the crown-gingiva margin. The preoperative contour was used as the baseline to detect the immediate postoperative horizontal contour increase (HCI), and the immediate postoperative contour was used as another baseline to detect the 1-year follow-up horizontal contour decrease (HCD).
Time frame: At the 1-year follow-up
Marginal bone level assessment
X-ray images immediately postoperative (baseline) and at the 1-year follow-up were taken, and the distances from the most coronal bone-to-implant or bone-to-superstructure contact point to the reference point (neck margin of the implant) were measured at the mesial and distal sides of the implant; then, the data were averaged. Negative values were recorded when the contact point was at the root side of the reference point, and positive values were recorded when the contact point was at the crown side of the reference point. The data were calibrated with the known length of the implant to correct for distortion. The MBL changes were obtained by subtracting the baseline data from the 1-year follow-up data.
Time frame: At the 1-year follow-up