Prior investigators have evaluated the use of 2-octyl cyanoacrylate (glue) as a method to secure a variety of venous catheters including central/peripheral lines. There is a paucity of research evaluating the use of glue for arterial catheters. The investigators conducted a pilot study to test the null hypothesis that there would be no difference in failure rates between radial arterial lines (r-a-line) secured with glue vs. suture.
This was a prospective, randomized, controlled, trial for which the investigators enrolled a convenience sample of consenting, non-pregnant, adult patients who received an r-a-line in the ICU or ED at a community-based, teaching hospital. After randomization, lines were secured with either silk 0-0 suture or 2-octyl cyanoacrylate and, then, covered by chlorhexidine gluconate dressing. Patients were followed for duration of line placement and for the occurrence of premature line failure. Categorical data were analyzed by chi-square; continuous data by t-tests.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
SUPPORTIVE_CARE
Masking
NONE
Enrollment
70
The specific intervention will be securing radial arterial catheters with either skin adhesive or suture material. Both are largely accepted to be standard of care but to date there is a paucity of literature directly comparing the two for radial arterial lines. During the intervention the placement of radial arterial catheters will be done via standard sterile procedure and using seldinger technique which involves using a guidewire to slide the arterial catheter into the radial artery. After the catheter is placed, it will be secure with either straight suture with a cutting needle or via skin adhesive. Following securement, the area will be cleaned and a Tegaderm dressing with biopatch will be placed over the catheter. Data will be collected immediately after the procedure including length of procedure and complications as well as via chart review to determine the length of time the catheter was in place and evidence of premature failure.
The specific intervention will be securing radial arterial catheters with either skin adhesive or suture material. Both are largely accepted to be standard of care but to date there is a paucity of literature directly comparing the two for radial arterial lines. During the intervention the placement of radial arterial catheters will be done via standard sterile procedure and using seldinger technique which involves using a guidewire to slide the arterial catheter into the radial artery. After the catheter is placed, it will be secure with either straight suture with a cutting needle or via skin adhesive. Following securement, the area will be cleaned and a Tegaderm dressing with biopatch will be placed over the catheter. Data will be collected immediately after the procedure including length of procedure and complications as well as via chart review to determine the length of time the catheter was in place and evidence of premature failure.
CHRISTUS Spohn Hospital Corpus Christi - Shoreline
Corpus Christi, Texas, United States
Length of time which the catheter remained in place
Primary outcomes measured were length of time of which the catheter remained in place and causes of premature failure, if it occurred.
Time frame: 12 months
Cause of premature failure (if occurred)
Primary outcomes measured were length of time of which the catheter remained in place and causes of premature failure, if it occurred.
Time frame: 12 months
Evaluation of patient demographics for line failure
Secondary outcomes included an evaluation of patient and line placement demographics for line failure between both suture and skin glue groups.
Time frame: 12 months
Evaluation of line placement for line failure
Secondary outcomes included an evaluation of patient and line placement demographics for line failure between both suture and skin glue groups.
Time frame: 12 months
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.