It is a cross-sectional, randomized, and single-center study with a duration of 6 months. The study will follow the STROBE guidelines for cross-sectional studies and CONSORT 2024. The main objective is to evaluate the validity and reliability of two devices in measuring grip strength and muscle fatigability in community-dwelling older adults.The study will include community-dwelling older adults of both sexes over 60 years of age.
Design: It is a cross-sectional, randomized, and single-center study with a duration of 6 months. The study will follow the STROBE guidelines for cross-sectional studies and CONSORT 2024. The main objective is to evaluate the validity and reliability of the Device 1 and Device 2 devices in measuring grip strength and muscle fatigability in community-dwelling older adults. It will be carried out in two stages: In a first moment the criterion and interobserver validity will be assessed and in a second moment the intraobserver validity. Participants will be randomly assigned to one of the 6 arms to follow different orders of the devices (Device 1, Device 2 or Jamar). Population: community-dwelling older adults of both sexes over 60 years of age. Procedures: The investigators will schedule each participant for the initial assessment day. Using a table of random numbers, they will be assigned one of the arms. All participants have previously read, signed and given their written informed consent. An interview will be conducted in which age, sex and medication will be collected; an anthropometric and functional assessment will be performed. The functional tests include the 30-second squat test and grip strength tests using the Jamar, Device 1 and Device 2. Three repetitions will be performed with each device, allowing 30 seconds between repetitions and 3 to 5 minutes between devices. After 20 minutes the test will be repeated again on the devices for interobserver validation. 5 to 10 days later, tester 1 will repeat the grip test with the same effort to assess intraobserver reliability. Sample size: Similar studies validating grip strength devices compared to the Jamar showed an excellent correlation (ICC \> 0.90). With an estimated ICC of 0.90 ± 0.05 and an alpha risk of 5%, 348 participants are required for the training study. Variables: Sociodemographic (age, sex, hand dominance, number of medication types), anthropometric (height, weight, BMI and SMI), strength and fatigability (total number of repetitions in 30sCS, maximal grip strength (HGS), fatigue resistance (FR) and grip work (GW)) and device preference. Statistical analysis: Maximal strength and fatigability will be analyzed by means of means, standard deviations and statistical tests. Concordance between devices will be assessed using the Kappa coefficient and the Bland-Altman concordance index. ROC curves will be used to determine sensitivity and specificity, and data will be analyzed by gender. Results will be considered statistically significant if p \< 0.05, and IBM SPSS Statistics v28.0 will be used for analysis.
Study Type
OBSERVATIONAL
Enrollment
413
As this is a cross-sectional validation study, there is no intervention.
University of Salamanca
Salamanca, Salamanca, Spain
2. Hand grip test
Measurement of hand grip strength using a hand-held dynamometer. Values shall be recorded with all three devices.
Time frame: 2 weeks
Body Mass Index (BMI)
Is a mathematical ratio that associates the mass and the size of an individual BMI = weight / height \^2
Time frame: 2 weeks
4. Appendicular Skeletal Muscle mass Index (SMI)
Is a mathematical ratio that associates the muscle mass and the size of an individual SMI = appendicular muscle mass / height \^2
Time frame: 2 weeks
30 seconds chair stand test (30sCS)
Test that measures the number of times you perform the maximum number of squats on a chair in 30 seconds. The more squats the better functionally.
Time frame: 2 weeks
Fatigue resistance (FR)
Time taken to lose 50% of the maximum recorded grip strength.
Time frame: 2 weeks
Grip work (GW)
Value resulting from multiplying the maximum grip force by the fatigue strength by 0,75. It is measured in watts.
Time frame: 2 weeks
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.