During this IIT, the MSOT (Multispectral Optoacoustic Tomography ) Acuity Echo will be used to scan participants with Peripheral Arterial Disease assess MSOT Multispectral Optoacoustic Tomography (single-wavelength and hemoglobin-related parameters) in the Tibialis Anterior, and flexor hallucis brevis, at multiple time-points before, during and after interventional Lower Extremity Revascularization (LER ). Primary aim of the study ist the Comparison of the difference between oxygenated, deoxygenated hemoglobin and oxygenation in the tibialis anterior, and flexor hallucis brevis, at multiple time-points before, during and after interventional Lower Extremity Revascularization.
Study Type
OBSERVATIONAL
Enrollment
55
MSOT Multispectral Optoacoustic Tomography, single-wavelength, HbT, Hb, HbO2, collagen and mSO2 (700-1.100 nm wavelength range, in 10 nm increments) in the tibialis anterior and flexor hallucis brevis, at multiple time-points before, during and after interventional LER Lower Extremity Revascularization .
MSOT Multispectral Optoacoustic Tomography,
single-wavelength, HbT, Hb, HbO2, collagen and mSO2 (700-1.100 nm wavelength range, in 10 nm increments) in the tibialis anterior and flexor hallucis brevis, at multiple time-points before, during and after interventional LER Lower Extremity Revascularization .
Time frame: baseline pre LER, 30 minutes post LER, 24 hours post LER, 48hours post LER