Around 1.5 billion peripheral intravenous catheters (PIVCs) are sold yearly, with up to 90% of hospitalized patients receiving one, yet failure rates can reach 69%, often due to phlebitis, infiltration, occlusion, or dislodgement. These complications can collectively be named mechanical complications. This study aims to assess a new device's effectiveness in reducing mechanical complications associated with PIVCs through a non-inferiority randomized trial at two sites. A total of 548 patients will be recruited, with primary outcomes focused on complication rates and secondary outcomes examining adverse events, healthcare feedback, and economic impacts.
It is estimated that around 1.5 billion PIVC are sold yearly throughout the globe, and placing them is one of the most common invasive procedures in hospitalised patients, with up to 90% receiving one, yet there is a failure rate of up to 69%.1-5 Some of the most common causes of failure are considered to be phlebitis, subcutaneous infiltration, occlusion and dislodgement. These failure rates vary widely throughout the globe, where published data suggests rates of 8-44% for phlebitis, 5-21% for infiltration, 7.6-16% for occlusion and 5-10% for dislodgement.4,6-12 Phlebitis, commonly defined as an inflammatory process in the wall of a vein, resulting in a blood clot formation; while infiltration is defined as the inadvertent leakage of a solution into the surrounding tissue; occlusion is defined as catheter failure due to blockage, and dislodgement the accidental/ in adverted removal of the PIVC before intended.13 Previous studies have suggested that mechanical irritation could be an important factor resulting in PIVC failure.14-16 In the case of phlebitis, mechanical movements against the endothelial wall could initiate a cascade of prothrombotic events resulting in the formation of a blood clot, something that has been demonstrated in a simulated environment.14,17,18 Furthermore micromechanical movements of the PIVC could eventually lead the PIVC to migrate from within the vessel wall to be unintentionally placed outside the vessel, yet, still in the surrounding tissue causing infiltration. Occlusion is the sudden block of the PIVC, where flushing or aspirating from the PIVC is not possible. Dislodgement of a PIVC is the act of mechanical movement of the PIVC from the intravascular space to the surrounding environment outside of the body. Therefore, there is a need to investigate potential new methods for prevention of these mechanical complications, and one method could be in the reduction of mechanical forces acting on the vessels. The aim of this study is to investigate the safety and effectiveness of a new medical device in reducing the number of mechanical complications during IV therapy. To answer this aim, a non-inferiority randomized clinical trial will be executed at two sites, where patients having a vascular access will be examined in a systematic fashion. Inclusion criteria are: having VAD, \>18 years of age, speak local language, absence of signs of phlebitis or infiltration, and a signed consent form. Exclusion criteria are: VAD for sampling only, pregnancy, unable to obtain informed consent, patients under palliative care and VAD for bolus infusion only. A total of 548 patients will be recruited to this study, and it is estimated to take 5 months to complete. The primary outcomes/endpoints are to investigate the rate of mechanical complications in the form of phlebitis, infiltration, occlusion and dislodgement. While secondary outcomes/endpoints will be identifying the frequency and severity of any adverse events, healthcare opinions on the device and the economic burden of the mechanical complications. No follow up is planned in this trial.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Enrollment
548
The interventional device is a coupling device intended to prevent mechanical complications during peripheral intravenous infusions. While control will not receive the device.
Centro Hospitalar e Universitário de Coimbra
Coimbra, Portugal
RECRUITINGParc Sanitari Sant Joan de Déu
Barcelona, Spain
COMPLETEDThe rate of mechanical complications of an IV therapy session using the device compared to using current 'state of the art'.
Mechanical complications are defied as following: * Phlebitis -inflammation of a vein based on clinical diagnosis * Infiltration - the process of accidental leakage of fluids out of the veins into peripheral tissue * Occlusion - blocked PIVC, where flushing or aspirating from the PIVC is not possible * Dislodgment - the process of accidental/ unintentional complete removal of the PIVC before scheduled removal
Time frame: Baseline PIVC data and immediatly after PIVC removal
Frequency and severity of any adverse events
Time frame: Through study participation (hospitlized in the ward), an average of 5 days
Healthcare workers opinion of investigational device
A questionnaire has been developed asking baseline data from healthcare worker. The questionnaire contains questions about 1) opinion about using the device again, 2) recommendation of the device, and 3) usage of the device for a relative. Each question is ranked from 0 to 5.
Time frame: Immediately after the intervention
The economic cost of these disruptions to your facility in terms of man-hours, and resources.
Time frame: Immediatly after PIVC removal