The use of zygomatic implants is a technique that is becoming more and more widespread in daily clinical practice, however, few professionals feel safe and confident in performing this type of procedure. We therefore believe that a line of research focused on simplifying this technique will have an extraordinary impact on the safety of both patients and surgeons. Currently, new surgical guides have emerged that guarantee greater precision in the placement of zygomatic implants. However, no comparative clinical studies have yet been performed to evaluate the degree of accuracy of guided implant placement compared to the conventional freehand technique.
The primary objective of the study is to study the accuracy of the use of guided surgical splints compared to traditional freehand zygomatic implant placement. The secondary objectives are: * To compare the magnitude of variations depending on implant length by superimposing postoperative CT scans using 3DSlicer® (http://www.slicer.org) and exocad® software. * To compare the magnitude of the variations depending on the location of the implant by superimposing postoperative and postoperative CT scans using 3DSlicer® (http://www.slicer.org) and exocad® software. * To assess the clinical relevance of cogomatic implant placement using guided surgical splinting on pain parameters and surgical time.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
DOUBLE
Enrollment
20
Placing extralarge implats for rahabilitation atrophic maxilla
Jesus
Madrid, Spain
RECRUITINGUCM
Madrid, Spain
RECRUITINGAccuracy of Surgical Guides in implant placement
Accuracy of Surgical Guides in terms of Radiological differences in implant placement. The primary outcome is to measure the differences existing between implant planificación and final implant placement. First, a computed tomography (CT) scan will be performed to plan the placement of the zygomatic implants. Once the implants have been placed in both groups, another CT scan will be performed to evaluate the following parameters using 3DSlicer® software (http://www.slicer.org). Three-dimensional lateral apical implant deviation and three-dimensional lateral neck implant deviation respect to the original digital planning will be evaluated by superimposing images. 3D lateral deviations will be measured in mm in relation with original planning. Also deviations in degrees between the original planning and the final placements will be evaluated.
Time frame: 12 months