Ventricular arrhythmias (VAs) are the leading cause of sudden cardiac death (SCD) worldwide. The implantable defibrillator (ICD) increases survival in patients at risk of VA, with data of superiority to antiarrhythmic drugs. Nevertheless, the ICD cannot prevent VAs, and shocks delivered by the device (appropriate and inappropriate) negatively impact patients' quality of life. Transcatheter ablation (TCA) is the percutaneous therapy that can eliminate VAs and prevent any recurrence. TCA is the state of the art for the treatment of drug-unresponsive VAs in patients with structural heart disease, but the prevalence of recurrence remains high (between 30% and 60%). For these reasons, several reports have recently appeared in the literature proposing a new solution for the treatment of VAs in which the use of external-beam body radiotherapy with stereotactic-radiosurgical technique (SBRT) is described. SBRT represents a rapid, noninvasive approach based on the delivery of high radiation doses of photons (25 Gy in a single fraction) to a precise location in cardiac tissue. SBRT has entered the latest 2022 European Society of Cardiology (ESC) guidelines on VAs as a "bailout therapy". Based on preliminary data in the oncology setting, proton therapy could allow further optimization of compliance of these therapeutic doses by preserving even more of the healthy heart part and thus reducing the cardiopulmonary toxicity of radiotherapy outside the ablation target. The investigators therefore propose an experimental (prospective interventional) study to evaluate the toxicity (primary endpoint) and efficacy (secondary endpoint) of proton radiosurgery for the treatment of VA with an enrollment of 21 patients. The primary endpoint is to evaluate the toxicity of proton radiotherapy in the acute phase (during the first 30 days of the procedure) and at 3, 6 and 12 months. A crucial part of the protocol will be the proper definition of the target to be irradiated, which will require the integration of different non-invasive cardiac imaging methodologies such as CT (Computed Tomography), MRI (Magnetic Resonance Imaging) and PET (Positron Emission Tomography), coupled with invasive and/or "non-invasive" body surface mapping with multi-electrode electrocardiogram (ECG) so as to obtain a "cardiac image" in which the myocardial scar and the arrhythmogenic region are fused.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
TREATMENT
Masking
NONE
Enrollment
21
STAR with a single dose of 25Gy(RBE) Proton Therapy
Cardiology Rovereto and Proton Therapy Trento, Azienda Provinciale per i Servizi Sanitari (APSS)
Trento, Italy, Italy
Toxicity of STAR with a single dose of 25Gy(RBE) applied with Proton Therapy
The primary endpoint will be the assessment of the toxicity of proton therapy and will be evaluated in the acute phase (during the first 30 days of the procedure) and at 3, 6, 12, 18, and 24 months. The incidence of Major Adverse Events (MAEs) related to, or presumed to be related, to proton therapy ablation will be assessed as percentage of patients with events compared to the total enrolled. The definition of MAEs (for the primary endpoint of the study) is identical to that of SAEs (as defined for reporting under Good Clinical Practice (GCP)) and can be found in the section "Serious Adverse Events (SAEs) / Major Adverse Events (MAEs) of the study protocol."
Time frame: Recording of MAEs for the first 24 months after therapy
Efficacy of STAR with a single dose of 25Gy(RBE) applied with Proton Therapy
The main secondary endpoint will be the efficacy endpoint, which will involve evaluating the procedural effectiveness of therapy at 3, 6 and 12, 18 and 24 months and is the percentage reduction in VT/VF (Ventricular Tachycardia/Ventricular Fibrillation) episodes occurring after the 2-month "blanking period," compared with the period before the proton ablation procedure (6 months). VT episodes will be classified as follows: * VT episodes \> 30 s, regardless of ICD intervention * ICD interventions on VT episodes by "antitachycardia pacing" (without shock delivery) * ICD interventions with appropriate DC shocks * Number of subjects with ≥ 50% reduction in the number of ICD treatments for VT (shock or antitachycardia pacing, ATP) comparing the 6-month period before proton therapy with the 8 months after proton therapy (excluding the 2-month blanking period after Proton Therapy). In addition, a series of other secondary toxicity and efficacy endpoints will be evaluated.
Time frame: Efficacy measures will be recorded for the first 24 months after therapy
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.