Nociception is the encoding and processing of noxious stimulation and is considered an objective indicator for monitoring pain. Currently, a new clinically-applied medical-engineering integrated monitoring device for noxious stimulation response has emerged. Its fundamental principle is based on the monitoring of electroencephalographic (EEG) activity, incorporating two monitoring parameters: the quantitative consciousness (qCON) index and the quantitative nociceptive (qNOX) index. This device enables more precise monitoring of anesthesia depth, quantification of patients' anesthesia analgesia and stress levels, and reliable monitoring of responses to noxious stimulation. During tracheal intubation for general anesthesia, when the qCON value falls within the range of 40 to 60 and the qNOX value is between 30 and 50, it indicates that the patient is in an appropriate state of sedation and analgesia. However, there is currently no universally acknowledged standard for the optimal qNOX reference range during conscious sedation endoscopy. Therefore, this study utilizes the noxious stimulation response index (qNOX) to monitor noxious stimulation during the procedure, aiming to identify the best timing for inserting the endoscope during conscious sedation endoscopy and explore the appropriate range of qNOX for this purpose.
This is a multicenter clinical study. Study Objective: To explore the reasonable range of the qNOX and the optimal timing for gastroscopy and colonoscopy during intravenous sedation-assisted endoscopic examinations. Study Protocol: A total of 900 patients undergoing intravenous sedation-assisted digestive endoscopy in the outpatient clinics of the participating institutions were selected. Among them, 450 patients undergoing gastroscopy were divided into a propofol group (GP group) and a propofol combined with low-dose sufentanil group (GSP group); 450 patients undergoing colonoscopy were divided into a propofol group (CP group) and a propofol combined with low-dose sufentanil group (CSP group). The bispectral index monitor (Apollo-9000A) was used to monitor the qCON and qNOX of patients during intravenous sedation-assisted digestive endoscopy. The values of qCON, qNOX, SBP (systolic blood pressure), DBP (diastolic blood pressure), MAP (mean arterial pressure), HR (heart rate), SpO2 (peripheral capillary oxygen saturation), and MOAA/S (Modified Observer's Assessment of Alertness/Sedation) scores at different time points during gastroscopy and colonoscopy were observed and recorded. The occurrence of adverse events during and after the examinations was also documented.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
OTHER
Masking
SINGLE
Enrollment
900
During gastroscopy and colonoscopy procedures, the Bispectral Index Monitor (Apollo-9000A) is utilized to monitor patients' quantitative consciousness index (qCON) and quantitative nociception index (qNOX).
China,Chongqing The First Affiliated Hospital of Chongqing Medical University
Chongqing, Chongqing Municipality, China
RECRUITINGThe value of qNOX
The value of qNOX when the gastroscope passes through the pharynx or the colonoscope passes through the anus.
Time frame: Start of the procedure,when the gastroscope passes through the pharynx or the colonoscope passes through the anus.
The values of qCON 、 qNOX at different time
The Values of qCON 、 qNOX at different time points during gastroscopy and enteroscopy ① Time points for gastroscopy: Baseline value (T0), Loss of consciousness (T1), Before insertion of the gastroscope (T2), Passage of the gastroscope through the pharynx (T3), After insertion of the gastroscope (T4), Examination completion (T5), Awakening (T6), Discharge from recovery room (T7). ② Time points for colonoscopy: Baseline value (T0), Loss of consciousness (T1), Before insertion of the colonoscope (T2), After insertion of the colonoscope into the anus (T3), Descending colon (T4), Splenic flexure (T5), Hepatic flexure (T6), Examination completion (T7), Awakening (T8), Discharge from recovery room (T9).
Time frame: Up to 1 hours, from the moment the patient enters the endoscopy procedure room until they exit it
The values of qCON 、 qNOX under special events
The values of qCON, qNOX score during coughing, body movement, biopsy, and polypectomy that occurred during the examination.
Time frame: Up to 1 hours, from the moment the patient enters the endoscopy procedure room until they exit it
The values of SBP、DBP、 MAP at different time
The Values of SBP、DBP、 MAP at different time points during gastroscopy and enteroscopy ① Time points for gastroscopy: Baseline value (T0), Loss of consciousness (T1), Before insertion of the gastroscope (T2), Passage of the gastroscope through the pharynx (T3), After insertion of the gastroscope (T4), Examination completion (T5), Awakening (T6), Discharge from recovery room (T7). ② Time points for colonoscopy: Baseline value (T0), Loss of consciousness (T1), Before insertion of the colonoscope (T2), After insertion of the colonoscope into the anus (T3), Descending colon (T4), Splenic flexure (T5), Hepatic flexure (T6), Examination completion (T7), Awakening (T8), Discharge from recovery room (T9).
Time frame: Up to 1 hours, from the moment the patient enters the endoscopy procedure room until they exit it
The values of SBP、DBP、 MAP under special events
The values of SBP、DBP、 MAP during coughing, body movement, biopsy, and polypectomy that occurred during the examination.
Time frame: Up to 1 hours, from the moment the patient enters the endoscopy procedure room until they exit it
The values of HR at different time
The Values of HR at different time points during gastroscopy and enteroscopy ① Time points for gastroscopy: Baseline value (T0), Loss of consciousness (T1), Before insertion of the gastroscope (T2), Passage of the gastroscope through the pharynx (T3), After insertion of the gastroscope (T4), Examination completion (T5), Awakening (T6), Discharge from recovery room (T7). ② Time points for colonoscopy: Baseline value (T0), Loss of consciousness (T1), Before insertion of the colonoscope (T2), After insertion of the colonoscope into the anus (T3), Descending colon (T4), Splenic flexure (T5), Hepatic flexure (T6), Examination completion (T7), Awakening (T8), Discharge from recovery room (T9).
Time frame: Up to 1 hours, from the moment the patient enters the endoscopy procedure room until they exit it
The values of HR under special events
The values of HR during coughing, body movement, biopsy, and polypectomy that occurred during the examination.
Time frame: Up to 1 hours, from the moment the patient enters the endoscopy procedure room until they exit it
The values of MOAA/S at different time
The Values of MOAA/S at different time points during gastroscopy and enteroscopy ① Time points for gastroscopy: Baseline value (T0), Loss of consciousness (T1), Before insertion of the gastroscope (T2), Passage of the gastroscope through the pharynx (T3), After insertion of the gastroscope (T4), Examination completion (T5), Awakening (T6), Discharge from recovery room (T7). ② Time points for colonoscopy: Baseline value (T0), Loss of consciousness (T1), Before insertion of the colonoscope (T2), After insertion of the colonoscope into the anus (T3), Descending colon (T4), Splenic flexure (T5), Hepatic flexure (T6), Examination completion (T7), Awakening (T8), Discharge from recovery room (T9).
Time frame: Up to 1 hours, from the moment the patient enters the endoscopy procedure room until they exit it
The values of MOAA/S under special events
The values of HR during coughing, body movement, biopsy, and polypectomy that occurred during the examination.
Time frame: Up to 1 hours, from the moment the patient enters the endoscopy procedure room until they exit it
Adverse events
Adverse events during gastroscopy and enteroscopy were recorded, including hypotension, hypertension, tachycardia, bradycardia, respiratory depression, hypoxemia, cough, body movement, nausea, vomiting, hiccup, injection pain, abdominal pain, abdominal distension, reflux aspiration.
Time frame: Up to 1 hours, from the moment the patient enters the endoscopy procedure room until they exit it
Adverse events and complications after examination
Bleeding, dizziness, blurred vision, nausea, vomiting, abdominal pain, abdominal distension were followed up 24h after the examination