This clinical trial tests the how well an ultrasound with subharmonic imaging and the subharmonic aided pressure estimation (SHAPE) technique works in identifying portal hypertension (PH). An ultrasound takes pictures of the inside of the body by bouncing sound waves off organs. PH is high blood pressure in the vein that carries blood to the liver from the stomach, small and large intestines, spleen, pancreas, and gallbladder. The complications associated with PH are clear only after severe liver dysfunction or liver cirrhosis develops and are accompanied by relatively high mortality rates (20-70% mortality within 2 years). Thus, identifying PH earlier is beneficial. The hepatic venous pressure gradient (HVPG) obtained using an invasive catheterization procedure remains the standard for assessing PH. However, using this invasive procedure to assess PH prevents frequent pressure monitoring. Thus, a noninvasive technique to estimate PH is beneficial not only for diagnosis but also for monitoring treatment and disease progression. The SHAPE technique is a noninvasive ultrasound-based imaging technique that can estimate pressure with an ultrasound contrast agent. A noninvasive technique using an ultrasound with subharmonic imaging and the SHAPE technique may work in identifying PH.
PRIMARY OBJECTIVES: I. To evaluate if SHAPE with perflutren lipid microspheres (Definity) microbubbles identifies patients with clinically significant PH. II. To evaluate if addition of subharmonic imaging-based perfusion parameters derived from time intensity curves and shear wave elastography (SWE) measurements increase the diagnostic confidence of detecting PH. OUTLINE: Patients receive Definity intravenously (IV) once on study. Additionally, patients undergo ultrasound with and without SHAPE technique as well as standard of care liver biopsy on study. After completion of study intervention, patients are followed up for 30 minutes.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
DIAGNOSTIC
Masking
NONE
Enrollment
60
Ancillary studies
Undergo liver biopsy
Undergo ultrasound with SHAPE technique
Given IV
Undergo ultrasound
Mayo Clinic in Arizona
Scottsdale, Arizona, United States
RECRUITINGMayo Clinic in Florida
Jacksonville, Florida, United States
RECRUITINGMayo Clinic in Rochester
Rochester, Minnesota, United States
RECRUITINGClinically significant portal hypertension (PH)
Will evaluate if subharmonic aided pressure estimation with Definity microbubbles identifies patients with clinically significant PH.
Time frame: Baseline (at time of ultrasound)
Diagnostic confidence
Will evaluate if the addition of subharmonic imaging-based perfusion parameters increase the diagnostic confidence of detecting PH.
Time frame: Baseline (at time of ultrasound)