The purpose of this study is to find out if manual stimulation of the vagus nerve is possible. The vagus nerve is a largely-internal nerve that controls many bodily functions, including stomach function. The hope is that electrically stimulating the nerve around the external ear will also stimulate the internal vagus nerve.
The purpose of this study is to find out if it is possible to gain access to the vagus nerve which is largely an internal nerve that controls stomach function. The hope is to gain access to the internal vagus nerve by electrically stimulating the nerve around the external ear. If this is possible to do this then there is hope that this will help the treatment of patients with nausea and vomiting and disordered stomach function. Healthy subjects and subjects with gastroparesis will be recruited. Subjects will undergo transcutaneous stimulation of the auricular branch of the vagus nerve and also undergo blood draw before, after stimulation and later a third draw after a period of no stimulation. Healthy subjects will also undergo vagal maneuver using the Multi Array Electrodes (MEA). Subjects will also complete health history questionnaires.
Study Type
INTERVENTIONAL
Allocation
NON_RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Enrollment
21
Cervical neck electrodes used in this part of the study will include the multi electrode array (MEA). The MEA can be placed on either side of the neck over the area of the vagus nerve to record any electrical activity that might occur during the baseline period. Two ECG electrodes are placed either one on each arm or on the chest for measurement of the electrocardiogram (ECG). Three ECG electrodes are placed on the abdomen in a line parallel to the longitudinal axis of the stomach to record the electrogastrogram (EGG). A onetime baseline recording will be made for 20 minutes after which the subject will be discharged from the study.
Indiana University Hosptial
Indianapolis, Indiana, United States
Vagal Nerve Activation
To measure the amplitude of vagal nerve compound action potentials in gastroparetic subjects with symptoms of nausea and vomiting with skin electrodes over right and left vagus nerve during ABVN stimulation and also during the vagal maneuvers phase
Time frame: 3 hours
Measure changes in chest diameter resulting from breathing
To measure and evaluate respiratory variation of heart rate.
Time frame: 3 hours
Amplitude surface electrogastrogram
To measure changes in the amplitude of the surface electrogastrogram during ABVN and also during the vagal maneuvers phase.
Time frame: 3 hours
Heart rate variability
To measure the Heart rate variability(HRV), vagal nerve compound action potentials and electrogastrogram in subjects undergoing VNS Therapy for focal or partial seizures.
Time frame: 3 hours
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.