The aim of this study was to compare the three approaches: open technique, modified Seldinger's technique and closed ultrasound-guided Central venous catheterization insertion for central line insertion in infancy as regards safety, success of cannulation, technique time, and preservation of the patency of the internal jugular vein.
Central venous catheterization is an essential technique in the intensive care units , for the administration of life-saving treatments including total parenteral nutrition, nutritional support, and intravenous medication. The internal jugular vein is often chosen because of its relatively larger size than the subclavian vein, lower risk of complications, and easy compressibility in case of bleeding. To facilitate Central venous catheterization, ultrasound guidance over anatomical guidance in closed techniques has been introduced bringing increased success rates, decreased catheterization times, and reduced complications. Open surgical insertion is a common method of tunneled catheter implantation in the past, but the percutaneous approach has recently gained more popularity . The modified Seldinger's insertion technique is a catheter over guide wire technique, based on the original Seldinger's technique, and has not been widely adopted in Intensive care units. However, the modified Seldinger's technique has been successfully introduced into Intensive care units, and it is now used as the only technique for peripherally inserted central venous catheter insertion . Central venous catheterization have become a mandatory part of clinical management in a variety of clinical circumstances in pediatric age groups. It allows resuscitation for intravascular fluid depletion and access for vasoactive medications and antibiotics, and it provides a means for hemodynamic monitoring and pacing. US guided closed technique is the updated use for insertion of IJV catheterization because it can both increase the success rate and decrease the complications related to Central venous catheterization placement
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
PREVENTION
Masking
NONE
Enrollment
35
The technique was performed following the descriptions of Farhadi et al. The infant was positioned in 30° (Trendelenburg's position), with a roll under his shoulders for neck extension and rotated to contralateral side of the surgical side to expose the incision site. Incision was done under sedation and pulse oximeter to monitor the oxygen saturation during the technique. Under complete aseptic technique, a small transverse incision 1cm was made on triangle bordered by the clavicle inferiorly and by the sternal and clavicular heads of the sternomastoid muscle medially and laterally. With blunt dissection we separate the two heads of the sternomastoid exposing the internal jugular vein . Then internal jugular vein cut down was performed and catheter inserted through it, all internal jugular vein venotomies were repaired as needed by 6/0 Polypropylene (Prolene®) suture and the wound was closed by absorbable polyglactin (Vicryl) suture
After proximal and distal control of the vein, a 24-G. cannula was carefully inserted directly to the internal jugular vein . The guidewire was inserted through the cannula, then the cannula was removed. A size 4-5 French short length catheter was passed and brought out through the guidewire, then the guidewire was removed. The wound was closed after the correct catheter position and good haemostasis was obtained; the area was covered with sterile dressing.
Tanta University
Tanta, Egypt
success of cannulation
Central venous cannulations in pediatric patients using each technique
Time frame: 20 minutes
Technique time
Time frame: within 30 minutes
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Ultrasound probe was connected to ultrasound unit and focused with ultrasonic gel and wrapped in a sterile plastic sheath. By wrapping the transducer in a sterile sheath, the probe place perpendicular to the long axis of the vessel, standard US two-dimensional (2D) imaging was used to visualize the vein in the short-axis view as a circle. Catheterization was performed under continuous dynamic observation of real-time 2D images. Insertion needle was advanced through the skin under US guidance into the internal jugular vein . A guidewire was then placed through the needle into the vein, and the needle was removed. Then catheter was inserted over the wire into internal jugular vein .