Although an intraoral scanner IOS can offer the clinician a completely digital workflow, achieving trustworthy digital scans in edentulous jaws is challenging because of the lack of fixed anatomical landmarks. From this perspective, several methods have been proposed to improve the accuracy of digital scanning, however, related results remain inconclusive, and previously proposed devices have had limitations, such as bulkiness, excessive manufacturing requirements, and poor commercial applicability. Thus, this study aims to clinically compare the effect of conventional versus photogrammetry intraoral scanning methods on the passive fit of mandibular all-on four screw-retained frameworks.
The current study will be designed to be a crossover, double-blinded randomized clinical trial. Eighteen edentulous patients will be selected to share in the study to be rehabilitated by screw-retained prostheses following the all-on-4 protocol. After guided implant surgery, patients will be immediately restored by screw-retained acrylic provisionals following the traditional denture conversion technique. The definitive prosthesis will be fabricated after osseointegration starting with the intraoral scanning procedure; each patient will be subjected to three different scanning methods that can enhance the existing IOS workflow; for group I, the Medit i600 will be used to obtain direct intraoral scans while the scan bodies are combined with extra photogrammetry system scanning assistance, for group II, Medit i600 direct intraoral scans will be obtained while applying basic simple splinting along with incorporating a unique tip in the scanning protocol and scanner software, for group III, Medit i600 direct intraoral classical scans will be obtained while applying only a basic simple splinting. The STL file obtained from the different scans will be sent directly to the dental laboratory and three CAD/Milled frameworks will be realized based on the acquired scans. The jigs' passivity will be tested in the patient's mouth by the single screw test followed by the screw resistance test and the screw resistance test parameter will be calculated. The results will be collected for statistical analysis.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
TRIPLE
Enrollment
16
The Photogrammetry-assisted intraoral scanning; will be executed using the MUA-compatible ioConnect ® photogrammetry system components exactly in the same sequence as recommended by the manufacturer
The scan bodies will be mounted over the MUA and loosely connected with a power chain before the Medit scanner single-shot scanning procedure. Using the additional scan option in the Medit scanner software, another single-shot scan will be obtained and superimposed to the first scan yielding a color map that reflects the accuracy of the obtained scan and directs a highly precise final scan.
The Medit i600 direct intraoral classical scans will be obtained while applying only a basic simple splinting
faculty of dentistry Ain-Shams university
Cairo, Abbasia, Egypt
Clinical assessment of passive fit following the latest update of the one screw test
Three CAD/Milled frameworks for each subject will be realized based on the acquired scans. The passive fit of each framework will be assessed intraorally following the Sheffield test: The test Part I involves checking the fit of the framework using finger pressure then tightening one of the most distal abutment screws. when an accurate horizontal and perpendicular fit viewed under magnification (will be categorized as 3 or excellent). If a slight "shadow" or suspicion of a vertical discrepancy, exists between the framework and abutment, a satisfactory passive fit will be confirmed by part 2 of test; If a suspected fit discrepancy can be closed using a 13mm wide modelling wax strip, representing 20 KN/m2 pressure load without distorting, then the fit is deemed to be clinically acceptable (categorized as 2 or good). If the wax does distort or is unable to close the discrepancy, will be (categorized as 1 or poor). this categorization arbitrarily defined by authors.
Time frame: six months
objective assessment of clinical passive fit using the screw resistance test parameter
The screw resistance test will be used to objectively evaluate and compare the passive fit of the three frameworks for each subject by calculating the SR parameter as the difference of the rotation angles of each screw in the passive and the non-passive situations by the formula: SR = SR passive - SR non-passive.
Time frame: six months
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.