The structural deterioration process of the implanted bioprosthesis in tricuspid position for tricuspid valve pathology is gradual and irreversible and includes many changes, such as pannus growth, leaflet fibrosis and calcification, delamination of the connective tissue, ruptures and perforations of leaflets. In the great majority of cases SVD consists of leaflet calcium deposits and can be clinically associated with young age, hypercholesterolemia, hypertension, diabetes mellitus, renal failure. The long term durability of these bioprosthesis is still missing.
It is not clear if the same biochemical, hemodynamic and immunological mechanisms leading to native valve calcification can cause bioprosthetic SVD. We hypothesize that the mechanisms protecting the native valve from calcification in the insufficiency disease may subsequently protect also the bioprosthetic valve from calcific SVD. In such a case, considering also the reduced incidence in insufficiency patients of prosthesis-patient mismatch, supposedly associated with increased risk of SVD, indication for bioprosthetic valve use could be expanded in patients with insufficiency. Because of the rising demand of bioprosthetic valve implantation, even a few years increase in the expected durability of the BHV, although limited to a defined population of patients, will have a very relevant clinical impact. We aim to perform a retrospective, multi-center, observational study. All patients undergoing elective tricuspid valve replacement from 2000 to 2020 who met the inclusion criteria for the study (described in the dedicated section) will be enrolled in the study. These patients will be followed-up as part of routine care, and information about the clinical status, NYHA functional class, possible rehospitalization, possible cardiovascular events and postoperative echocardiography will be available for analysis. Once consent is given, and if required by local governance, pre-, intra- and post-operative data will be collected in a dedicated, structured, database.
Study Type
OBSERVATIONAL
Enrollment
500
All operations were performed through median longitudinal sternotomy or mini-sternotomy or minitoracothomy Intraoperative transesophageal echocardiography (TOE) was used in all patients. Arterial cannulation was central and venous cannulation was achieved with a common two-stage cannula in the right atrium or from peripheral access. Left ventricle was vented through the right superior pulmonary vein. In minimally invasive procedures, venous cannulation was achieved percutaneously. Myocardial protection was achieved by administration of cold crystalloid or blood cardioplegia at the surgeon's discretion in an antegrade (indirect or selective) or retrograde fashion.. All the prosthesis were be implanted with supranular technique and 2-0 U-shaped pledgeted sutures.
Cardio-Thoracic Surgery Department - Heart & Vascular Centre - Maastricht University Medical Centre (MUMC+)
Maastricht, Netherlands
Long term durability
Long term durability of the tricuspid bioprosthesis in terms of structural valve deterioration or /and associated complications. Echocardiographic parameters will be used. Continous variables will be implied.
Time frame: 20 years
Long term survival
Long term survival, event free survival, freedom from reoperations and hospitalization.
Time frame: 20 years