In this study, wearable multi-modal microsensors were deployed to simultaneously capture seismocardiography (SCG) and electrocardiography (ECG) signals, delineating the exercise-load-dependent responsiveness of SCG-ECG dynamic coupling during graded-speed treadmill protocols.
The heart adapts to varying exercise loads primarily by augmenting heart rate and contractility to achieve matching increases in cardiac output. However, whether there exists an intrinsic triaxial regulatory mechanism governing the interdependencies among 'exercise load - heart rate response - contractility response' remains unknown. In this study, participants performed treadmill exercise at multiple speed gradients (3-8 km/h). Seismocardiography (SCG) signals were captured via an inertial measurement unit (IMU) positioned on the precordium and were used to characterize mechanical cardiac contractility. Single-lead precordial ECG provided heart rate dynamics, while CPET-derived oxygen uptake (VO₂) indexed exercise intensity. The primary objectives were to delineate SCG-ECG responsivity patterns under graded exercise intensities and quantify potential intrinsic laws linking exercise load, heart rate adaptation, and contractility modulation.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
BASIC_SCIENCE
Masking
NONE
Enrollment
270
Healthy participants will undergo a fixed experimental protocol of multi-stage treadmill speed walking/running wearing microsensors and a respiratory/metabolic testing mask.
Building 16, Lane 775, Hangdong Road, Shanghai
Shanghai, Shanghai Municipality, China
RECRUITINGChanges in Seismocardiography (SCG) Signal Amplitude (m/s²)
Peak-to-peak amplitudes of Seismocardiography (SCG) signals will be measured using a triaxial accelerometer (sampling rate: 500 Hz). The primary parameter assessed is the signal amplitude in meters per second squared (m/s²) per cardiac cycle. Values will be averaged over 30-second artifact-free epochs during rest and exercise stages.
Time frame: The entire test will be completed in approximately 90 minutes.
Changes in Electrocardiogram (ECG) R-R Intervals (ms)
R-R intervals, measured in milliseconds (ms), will be derived from a single-lead Electrocardiogram (ECG) recording (sampling rate: 250 Hz). The specific parameter assessed is the time duration between consecutive R-waves. R-peaks will be auto-detected and confirmed by amplitude and slope thresholds. Data will be averaged over 30-second epochs synchronized with SCG signals.
Time frame: The entire test will be completed in approximately 90 minutes.