Comparing the efficacy of superhigh-flux dialyzer with high-flux dialyzer in ESKD patient who have sepsis to improve mortality and sepsis outcome, an open label randomized control trial.
Sepsis in people who have ESKD is the risk of developing poor outcome. Cytokines play a role in the process of sepsis and cause the worsening clinical outcome despite definitive antibiotic treatment. Superhigh-flux dialyzer has a larger molecular weight cut off (MWCO) clearance, include cytokine, could contribute to improved sepsis management in individuals with ESKD. This study is conducted to prove the efficacy of super high-flux dialyzer comparing with high-flux dialyzer in case of mortality reduction for regular hemodialysis ESKD patients. Method This study is an open label single center randomized control trial. We randomized ESKD patients who have sepsis condition with high interleukin-6 (IL-6 \> 50 pg/ml). The participants were allocated to super high-flux dialyzer group and high flux dialyzer group, stratified with diabetes, vascular access, and septic shock. We excluded; patient who needed dialysis with continuous kidney replacement therapy, vulnerable patient, include pregnant woman, patient who closed and patient who expected to pass away within the 24 hours. We aim to enroll total 202 participants; divided equally in each arm. According to our protocol, non reused super high-flux dialyzer and high-flux dialyzer are used in the same assigned patient in first week without crossing over. The standard of care of sepsis and antibiotic are provided in both groups without intervening of researcher and our protocol. The primary endpoint is 28 days of mortality. The secondary outcome include cardiovascular death, rate reduction of IL-6 after dialysis, days of hospitalization, ventilator free days and complication of dialysis are also monitored.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Enrollment
Dialysis with Super High-flux dialyzer for intervention group
Dialysis with High-flux dialyzer for control group
Navamindhradhiraj university
Dusit, Bangkok, Thailand
RECRUITINGComparing the reduction of all cause death at 28 days
Comparing the efficacy to reduce all cause death at 28 days between Super High-flux dialyzer with High-flux dialyzer in ESKD with sepsis
Time frame: 28 days
Comparing the difference of blood level of IL-6, ESR, CRP and albumin, before and after of the first dialysis session, in each group.
Time frame: 7 days
The duration of inotrope weaning
Time frame: 14 days
The duration of hospitalization
Time frame: 28 days
Ventilator free days
Time frame: 28 days
The incidence of intradialytic hypotension
Time frame: 28 days
The incidence rate of complication of dialyzer in each group
The incidence rate of complication of dialyzer; allergic reaction, clotting of dialyzer etc.
Time frame: 28 days
The adequacy profile of dialysis in both groups
Time frame: 7 days
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
202