The purpose of this study is to evaluate whether a medical device called the Abdominal Aortic and Junctional Tourniquet - Stabilized (AAJT-S) can safely and effectively temporarily stop severe bleeding after childbirth (known as postpartum hemorrhage) when standard treatments fail. The main question the study aims to answer is: Can the AAJT-S device temporarily control life-threatening postpartum bleeding long enough to allow doctors to prepare for surgery and other definitive treatment?
This prospective, open-label, non-randomized, proof-of-concept study will assess the feasibility, safety, and preliminary clinical effectiveness of the Abdominal Aortic and Junctional Tourniquet - Stabilized (AAJT-S) device as a temporizing measure for severe postpartum hemorrhage (PPH) due to uterine atony that is unresponsive to standard first-line therapies. The study will be conducted in a tertiary referral center in Zaporizhzhia, Ukraine, located in a conflict-affected region with limited access to timely surgical intervention and blood products. Eligible participants will be adult postpartum patients (≥18 years) who develop primary PPH with blood loss exceeding 1,000 mL and who fail to respond to pharmacologic uterotonics and balloon tamponade. Patients with hemorrhage due to trauma, coagulopathy, or retained placental tissue will be excluded. Once standard management protocols are exhausted and eligibility is confirmed, the AAJT-S device will be deployed over the upper abdomen and inflated to 250 mmHg to achieve temporary occlusion of the abdominal aorta and inferior vena cava. The device is intended to reduce pelvic blood flow and thereby control hemorrhage during the critical window required to mobilize a surgical team, arrange blood transfusion, and secure anesthesia. The device will remain in place for a maximum of 60 minutes, consistent with published safety guidelines. Clinical endpoints will include time to bleeding control, hemodynamic stabilization, need for additional surgical intervention, and total blood loss. Safety endpoints will include thrombotic events, ischemic injury, infections, and any other adverse events related to device use. Data will be collected prospectively, including demographic characteristics, obstetric history, timing and duration of interventions, and perioperative outcomes. Descriptive statistics will be used to summarize findings, with no formal hypothesis testing due to the pilot nature of the study. All participants will receive routine inpatient follow-up, and longer-term outcomes will be assessed via scheduled in-person visits and structured telephone interviews at 6 and 12 months postpartum to evaluate for delayed complications and maternal recovery. The study is designed to generate preliminary data for further exploration of the AAJT-S device as a potential emergency tool for PPH management in resource-limited and crisis settings.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
TREATMENT
Masking
NONE
Enrollment
4
The AAJT-S is a non-invasive, externally applied medical device designed to achieve temporary occlusion of the abdominal aorta and inferior vena cava by inflating a pneumatic bladder to 250 mmHg. In this study, the device will be used as a temporizing measure for patients with severe postpartum hemorrhage unresponsive to standard uterotonics and balloon tamponade. The device will be applied horizontally over the upper abdomen and inflated using a built-in pressure gauge. The intended effect is to reduce pelvic blood flow and allow time for mobilization of surgical resources and blood transfusion. Maximum application time will not exceed 60 minutes, in accordance with established safety guidelines.
Olexandrivska Hospital
Zaporizhzhia, Ukraine
Time to Bleeding Control After AAJT-S Device Application
Defined as the time (in minutes) from inflation of the AAJT-S device to visible cessation of external vaginal bleeding in patients with severe postpartum hemorrhage due to uterine atony. Bleeding control will be determined by visual clinical assessment by the attending provider. This measure evaluates the immediate effectiveness of the intervention in stopping hemorrhage and buying time for definitive surgical management or transfusion.
Time frame: Within 10 minutes of AAJT-S device application
Total Measured Blood Loss (Pre- and Post-intervention)
Sum of blood loss (in mL), measured by pad/towel weights after AAJT-S use until definitive hemostasis.
Time frame: From onset of PPH until bleeding is definitively controlled (typically within 1-6 hours)
Incidence of Device-related Complications
Includes thrombotic events, ischemic injury, skin necrosis, or technical malfunction during/after AAJT-S use.
Time frame: From device application through hospital discharge (up to 7 days)
Hemodynamic Stabilization Time
Time from device inflation to achievement of target blood pressure (SBP ≥90 mmHg) and pulse \<110 bpm.
Time frame: First 60 minutes after AAJT-S application
Long-term Maternal Recovery Status
Assessed via follow-up calls and scheduled ultrasound visits at 6 weeks postpartum, including return to normal activity, presence of chronic pain, or menstrual abnormalities.
Time frame: At 6 weeks postpartum