Bioresorbable scaffold (BRS) was designed aiming to avoid the late adverse events associated with permanent metallic stents by providing temporary support to the vessel wall and promoting vessel remodeling, plaque reduction, and restoring vasomotion after its full absorption. As the first FDA-approved BRS, ABSORB BRS was associated with a significantly higher risk of late scaffold thrombosis compared with everolimus-eluting stent (EES). As a result, the ESC-EAPCI task force recommended that the current ABSORB BRS should not be preferred over conventional DES in clinical practice. To solve this dilemma, improved scaffold technology and optimal implantation techniques are necessary. The latest generation Firesorb BRS is a PLLA backbone scaffold system abluminally coated with poly(D, L-lactide) mixed with sirolimus using highly accurate and precise point spraying techniques. Compared to the ABSORB BRS, Firesorb features a thinner stent thickness (100-125 μm) while maintaining sufficient radial support, enabling faster degradation and a shorter duration of presence in the coronary. Additionally, inspired by the design of the Firehawk DES, its unique spot-coating process applies a single-sided coating layer exclusively to the stent's outer surface, enabling targeted drug release. Preclinical trials have demonstrated favorable performance for Firesorb, culminating in its approval by the National Medical Products Administration (NMPA) in 2024. Against these backgrounds, we have designed this trial to investigate whether the Firesorb BRS is non-inferior to the drug-eluting stent in terms of the Device-Oriented Composite Endpoint (DoCE) in patients undergoing percutaneous coronary intervention for de novo lesions.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Enrollment
2,000
The Firesorb BRS (MicroPort Medical, Shanghai, China) is a balloon-expandable scaffold with a highly crystallized PLLA backbone, abluminally coated with a poly(D, L-lactide) (PDLLA) matrix incorporating sirolimus (4 μg/mm) through highly accurate and precise point spraying techniques. The scaffold thickness is 100 μm for devices with diameters of 2.5 and 2.75 mm, and 125 μm for those ranging from 3.0 to 4.0 mm in diameter. There are two radiopaque markers at each end of the scaffold, which can identify the position of the stent under X-ray monitoring and help to accurately locate the scaffold.
The Firehawk™ stent (MicroPort Medical, Shanghai, China) is a third-generation balloon-expandable L605 cobalt chromium stent with abluminal grooves containing a biodegradable polymer, which provides controlled release of the anti-proliferative medicinal substance sirolimus. The polymer is biodegradable, leaving only the metallic stent as a permanent implant. The stent is mounted on a rapid exchange delivery catheter system. The unique abluminal grooves are scored at the outer surface of the struts (total strut thickness: 86 μm), with an average sirolimus dosage of 3 µg/mm stent lengths.
Xijing Hospital
Xi'an, Shannxi, China
RECRUITINGCumulative event rate of Device-oriented Composite Endpoint (DoCE)
DoCE is a composite clinical endpoint of cardiovascular death, target vessel myocardial infarction (TV-MI), and clinically and physiologically indicated target lesion revascularization (CPI-TLR).
Time frame: 36 months
Cumulative event rate of Device-oriented Composite Endpoint (DoCE)
Rates of the DoCE beside the time point of primary endpoint
Time frame: 1, 12, and 60 months
Cumulative event rate of Patient-oriented composite endpoint (PoCE)
PoCE is defined as a composite endpoint including all-cause death, stroke, myocardial infarction, and revascularization
Time frame: 1, 12, 36, and 60 months
Cumulative event rate of Target vessel failure (TVF)
TVF is defined as a composite endpoint including cardiovascular death, TV-MI and clinically and physiologically target vessel revascularization
Time frame: 1, 12, 36, and 60 months
Cumulative event rate of All-cause death
Individual components of PoCE
Time frame: 1, 12, 36, and 60 months
Cumulative event rate of Cardiovascular death
Individual components of the DoCE
Time frame: 1, 12, 36, and 60 months
Cumulative event rate of Stroke
Individual components of PoCE
Time frame: 1, 12, 36, and 60 months
Cumulative event rate of Myocardial infarction
Individual components of PoCE
Time frame: 1, 12, 36, and 60 months
Cumulative event rate of Target vessel myocardial infarction (TV-MI)
Individual components of DoCE
Time frame: 1, 12, 36, and 60 months
Cumulative event rate of Revascularization
Individual components of PoCE
Time frame: 1, 12, 36, and 60 months
Cumulative event rate of Clinically and physiologically indicated target vessel revascularization
Individual components of TVF
Time frame: 1, 12, 36, and 60 months
Cumulative event rate of Clinically and physiologically indicated target lesion revascularization (CPI-TLR)
Individual components of the DoCE
Time frame: 1, 12, 36, and 60 months
Cumulative event rate of Definite/Probable scaffold/stent thrombosis
According to ARC-2 definitions
Time frame: 1, 12, 36, and 60 months
Cumulative event rate of BARC defined type 3 or 5 bleeding events
Time frame: 1, 12, 36, and 60 months
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.