This study is looking at a new way to detect and monitor Barrett's esophagus (BE), a condition where the lining of the esophagus changes, increasing the risk of esophageal cancer. Currently, monitoring involves an endoscopy, where a camera is passed down the throat. While effective, endoscopy can be uncomfortable, uses significant healthcare resources, and sometimes involves sedation. This Swedish study explores a less invasive method called EndoSign®. EndoSign® is a small, swallowable capsule containing a sponge attached to a thin string. Patients swallow the capsule with water. It dissolves in the stomach over about 7 minutes, releasing the sponge. A trained nurse then gently pulls the sponge back up through the esophagus using the string, collecting cells along the way. The whole visit takes about 20-30 minutes. These cells are then sent to a lab to be checked for signs of BE and early changes (like TFF3, atypia, and p53) that might indicate a higher risk. The main goals of this study are: To see if using EndoSign® is practical (feasible) in several Swedish hospitals. To find out how patients feel about the EndoSign® test - is it acceptable and comfortable?. To check how safe the EndoSign® procedure is. To gather information needed to plan larger studies in the future. Who is participating? Around 70 adults (aged 18-84) across five Swedish hospitals, who have a confirmed diagnosis of BE and are already part of a surveillance program, are enrolled. Patients with certain alarm symptoms or those scheduled for immediate treatment are excluded. What happens in the study? Participants have a separate visit for the EndoSign® test, performed by a trained nurse. They also undergo their regular surveillance endoscopy (at least 90 days after the capsule test). Participants fill out questionnaires about their experience, comfort, and preferences after both procedures and again at 7 and 90 days. Potential Benefits \& Risks: EndoSign® could offer a simpler, less invasive, and potentially more comfortable way to monitor BE, which might reduce the need for some endoscopies. Early results show it is well-tolerated, with most patients preferring it over endoscopy, and has a high success rate and safety profile. Risks are low, with the most common being a temporary sore throat. Serious complications are considered very rare. This feasibility study aims to provide evidence on whether EndoSign® can be a valuable addition to BE surveillance in Sweden, potentially improving patient experience and resource use.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
DIAGNOSTIC
Masking
NONE
Enrollment
70
The intervention involves the EndoSign® Cell collection device (Cyted Ltd), a non-endoscopic method for esophageal sampling. Patients swallow a gelatine/HPMC capsule containing a sponge attached to a string. After \~7 minutes in the stomach for dissolution and sponge expansion, a trained nurse withdraws the sponge via the string, collecting cells. Optional throat anesthetic is offered. It can be performed without sedation in an outpatient clinic setting by a nurse. Samples undergo central analysis for TFF3, atypia, and p53, differing from standard biopsy histopathology. This study specifically evaluates its feasibility, acceptability, and nurse-led implementation in Swedish hospitals for Barrett's surveillance.
Sahlgrenska University Hospital
Gothenburg, Sweden
Skåne University Hospital
Lund, Sweden
Vrinnevi Hospital
Norrköping, Sweden
Ersta Hospital
Stockholm, Sweden
Karolinska University Hospital
Stockholm, Sweden
Technical Success Rate of the EndoSign® Procedure
Measures the rate of successfully completed EndoSign® procedures. Technical success is defined as a participant successfully swallowing the capsule (in a maximum of two attempts) and subsequent successful retrieval of the sponge by the nurse.
Time frame: Perioperative/Periprocedural
Patient-Reported Acceptability and Experience of the EndoSign® Procedure Compared to Gastroscopy
Measures and compares patient-reported outcomes for both the EndoSign® procedure and the surveillance gastroscopy. This includes Visual Analog Scale (VAS) scores (0-10) for discomfort and pain, which are measured immediately post-procedure and 15 minutes later for each respective procedure. It also assesses the patient's willingness to undergo each procedure again and their stated preference for future surveillance. Patient willingness to undergo the EndoSign® procedure again. Patient preference for EndoSign® vs. endoscopy for future surveillance.
Time frame: Perioperative/Periprocedural and at 7 and 90-day follow-ups. (Both Visits)
Safety of the EndoSign® Procedure
Incidence and rates of all Adverse Events (AEs), Serious Adverse Events (SAEs), Adverse Device Effects (ADEs), and Serious Adverse Device Effects (SADEs) are recorded following the EndoSign® procedure. Events are classified by severity and relatedness.
Time frame: Perioperative/Periprocedural and up to 90 days post-procedure.
Sample Adequacy of the EndoSign® Procedure
The proportion of retrieved EndoSign® samples are deemed adequate for full laboratory analysis, including TFF3 expression, atypia assessment, and p53 immunohistochemistry. An inadequate sample may be due to insufficient columnar cells or other factors preventing full analysis.
Time frame: Perioperative/Periprocedural
Risk Stratification Performance of the EndoSign® Test
Evaluation of the EndoSign® test's ability (using TFF3, atypia, p53, and clinical factors) to classify patients into low, moderate, and high-risk groups for harboring dysplasia. This includes calculating metrics such as Negative Predictive Value (NPV) for no dysplasia in low/moderate-risk groups and Positive Predictive Value (PPV) for dysplasia in the high-risk group, by comparing with endoscopic biopsy findings.
Time frame: Perioperative/Periprocedural
Assessment of Patient-Reported Health-Related Quality of Life using EQ-5D-5L
Measurement of general health-related quality of life using the EQ-5D-5L questionnaire, which assesses five dimensions (mobility, self-care, usual activities, pain/discomfort, anxiety/depression) and includes a self-rated health Visual Analog Scale (VAS).
Time frame: Perioperative/Periprocedural and at 7 and 90-day follow-ups.
EndoSign® Capsule Swallowing Attempts
The number of attempts required for patients to successfully swallow the EndoSign® capsule. Swallowing success contributes to the overall technical feasibility.
Time frame: Perioperative/Periprocedural