A Clinical Study Based on Magnetic Resonance Imaging of the Lungs to Assess the Efficacy of Thermal Vapor Ablation and Pulmonary Nodule Ablation in Chronic Obstructive Pulmonary Disease After Surgery. The efficacy of hot steam ablation for chronic obstructive pulmonary disease was evaluated using the innovative MRI sequence PREFUL\_MRI, and the efficacy of pulmonary nodule ablation was evaluated using the innovative MRI sequence GRASP\_MRI.
Study Type
OBSERVATIONAL
Enrollment
100
Shanghai chest hospital
Shanghai, Shanghai Municipality, China
RECRUITINGPREFUL-MRI Ventilation and Perfusion Parameters in Patients with COPD Following Lung Volume Reduction Surgery with Thermal Steam
Using the Phase-Resolved Functional Lung(PREFUL)-MRI dedicated post-processing analysis software, we can obtain images of the patient's lung ventilation and perfusion status.
Time frame: From enrollment to 6 months post-surgery
PREFUL-MRI Ventilation and Perfusion Parameters in Patients with COPD Following Lung Volume Reduction Surgery with Thermal Steam
Percentage of perfusion defect (QDP):Calculation of QDP based on PREFUL-MRI dedicated post-processing software
Time frame: From enrollment to 6 months post-surgery
PREFUL-MRI Ventilation and Perfusion Parameters in Patients with COPD Following Lung Volume Reduction Surgery with Thermal Steam
Percentage of ventilation defect (VDP):Calculation of VDP based on PREFUL-MRI dedicated post-processing software
Time frame: From enrollment to 6 months post-surgery
PREFUL-MRI Ventilation and Perfusion Parameters in Patients with COPD Following Lung Volume Reduction Surgery with Thermal Steam
Percentage of ventilation-perfusion match (VQM):Calculation of VQM based on PREFUL-MRI dedicated post-processing software
Time frame: From enrollment to 6 months post-surgery
Quantitative Hemodynamic Analysis Parameters Based on Tofts Model Using GRASP-MRI After Ablation of Solid Pulmonary Nodules
Quantitative parameters of GRASP-MRI images based on the Tofts model: Volume transfer coefficient(Ktrans)(/min):the rate transfer constant of gadolinium between plasma and tissue interstitium;
Time frame: From enrollment to 3 months post-surgery
Quantitative Hemodynamic Analysis Parameters Based on Tofts Model Using GRASP-MRI After Ablation of Solid Pulmonary Nodules
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Quantitative parameters of GRASP-MRI images based on the Tofts model: Interstitial volume(Ve)(0~1):the extracellular-extravascular volume;
Time frame: From enrollment to 3 months post-surgery
Quantitative Hemodynamic Analysis Parameters Based on Tofts Model Using GRASP-MRI After Ablation of Solid Pulmonary Nodules
Quantitative parameters of GRASP-MRI images based on the Tofts model: Kep: Backflow rate constant, reflecting the time constant for returning from EES to the vascular system, Kep = Ktrans / Ve.
Time frame: From enrollment to 3 months post-surgery