This is a multi-center, open-label, prospective and retrospective clinical outcomes study. Patient outcomes data is important for assessing the post-market safety and effectiveness of orthopedic medical devices. The purpose of this study is to collect clinical and patient outcomes and survivorship data for patients who have received or will receive an Exactech Knee System total knee arthroplasty (TKA) prosthesis manufactured or distributed by Exactech Inc (Gainesville, Florida, USA). Subjects will, or will have already, undergo/undergone TKA as prescribed by the operating surgeon in a medical center with appropriate facilities and appropriately trained personnel. Treatment will be with the knee replacement components described in this protocol. The surgical procedure shall be conducted according to the appropriate Surgical Technique (Reference #: 712-35-41 and 712-35-35 as applicable) and product labeling for an Exactech Knee System and in accordance with the standard of care of the operating surgeon. The medical devices and procedures used in this study are considered standard of care and are not considered investigational or experimental. Information about the subject's preoperative conditions, demographics, previous surgical procedures, devices used, surgical procedure, postoperative outcomes, radiographic outcomes, and adverse events should be collected according to the Protocol Activity Schedule below: Cohort 1. Prospective Subjects Enrolled in the study pre-surgery: Cohort 2. Retrospective-to-Prospective Subjects - Subjects Enrolled in the study post-surgery. Cohort 3. Retrospective Only Subjects - Data collection for the Retrospective Only Subjects will occur through a retrospective, observational, medical chart review. Visit \& Windows of data to be collected for all Cohorts: * Preoperative Visit- Within ≤ 3 months prior to surgery * Surgery/Discharge -Day of Surgery /Day of Discharge * 6 Week Post-Op Visit - (Porous cohort only) -3 weeks - 7 weeks * 6 Month Post-Op Visit - (Required for porous, optional for cemented) - 8 weeks - 26 weeks * 1 through 10 Year Post-Operative Follow-Up Visits (As per the surgeon's standard of care) - ±6 months Clinical Outcomes to be collected (only if available for Cohort 3): * Functional Performance * Range of Motion 1\. Patient Outcomes to be collected (only if available for Cohort 3): * Knee injury and Osteoarthritis Outcome Score for Joint Replacement Jr. (KOOS Jr.) * Knee Society Score (KSS) / Hospital for Special Surgery Score (HSS) * Oxford Knee Score (OKS) * Visual Analog Scale (VAS) for Pain and Patient Satisfaction 2\. Safety Outcomes: a. Adverse Events * Procedure-related adverse events, * Device related adverse events, * Readmissions, and Revisions b. Radiographic Outcomes (Assessment) (e.g., radiolucent lines, subsidence) c. Survivorship Rates - Kaplan Meier Analysis with a survivorship distribution function
3\. Sample Size and Justification Enrollment targets are based on, but not limited to, a sample size of 1879 primary subjects. Subjects will be enrolled based on a statistical estimation of the sample size needed to examine the primary outcome of survivorship (i.e., implant revision). The below table describes the distribution of enrollment. Additional subjects and component types may be enrolled beyond those described below. 1. Truliant CR, n=308 Cemented Femoral, n=154 Porous Femoral, n=154 Tibial Insert CR, n=154 Tibial Insert CRC, n=154 2. Truliant PS, n=610 Cemented Femoral, n=305 Porous Femoral, n=305 Tibial Insert PS, n=305 Tibial Insert PSC, n=305 3. Logic CR, n=308 Cemented Femoral, n=154 Porous Femoral, n=154 Tibial Insert CR, n=154 Tibial Insert CRC, n=154 4. Logic PS, n=610 Cemented Femoral, n=305 Porous Femoral, n=305 Tibial Insert PS, n=305 Tibial Insert PSC, n=305 5. Constrained Condylar Components, n=43 CC Cemented Femoral Components, n=43 CC Tibial Inserts, n=43 Each product's subgroups share the same parameters and assumptions resulting in equal sample size. Sample sizes are estimated by component to ensure sufficient clinical data on each Total Knee Arthroplasty (TKA) component from each system. Because a patient must undergo a TKA with both a tibial insert and a femoral component, that individual patient will count toward the sample size for each component. All calculations consider an estimated 40% attrition rate. The sample size calculations indicate the estimated width of the 95% confidence limits for the primary endpoint, namely implant survivorship at 10 years, based on data obtained from the literature. The calculation generated a proposed sample size sufficient to support a 10-year survivorship analysis. To ensure data consistency and quality across the planned study time points, the sample size estimation is applied to the prospectively enrolled subjects only. 4\. Data Collection Standard follow-up visits should be conducted to collect ongoing subject outcomes data. Electronic Patient Reported Outcomes (ePRO) may be available for subjects/sites to use for collection of safety data and patient reported outcomes. 5\. Data Collection Forms/Logs Paper Case Report Forms (CRFs) will be provided to assist sites with data collection, if requested. The use of paper CRFs may be implemented into the site's workflow completely, partially, or not at all. All data submitted to Exactech through an eCRF within the EDC must be verifiable in the patient's medical records or paper CRF. The original source of data submitted via electronic case report forms (eCRFs) for this study must be established prior to data collection. 6\. Data Recording: An electronic data capture (EDC) system will be used for recording data in this study. The EDC system provides an electronic version of the paper forms that allow for simple online completion and submission of the forms. The EDC system can be accessed from any computer with internet capabilities and provides a secure internet connection for data entry. Each site will need to be assigned login information (User ID and Password) from Exactech to access the forms. Sites will also be provided with the paper forms, if requested, so that all appropriate data can be collected during each subject visit. The data collected on the paper forms can then be used to complete the online (Internet) forms. 7\. Data Quality Assurance Investigative sites will be notified of incomplete or discrepant data so that corrections or additional data can be provided, as appropriate. Whether a site is using paper or electronic forms it is important to fill out each form as completely, legibly, and accurately as possible before submitting it to the Sponsor via eCRF. 8\. Outcome Assessment Analysis of clinical outcomes will be summarized using appropriate descriptive statistics (means, standard deviations, medians, minimum and maximums for continuous variables, and percentages for categorical variables at each point in time). 9\. Device Survival A Kaplan-Meier survival curve analysis will be performed to account for variability in length of follow- up. 10\. Complications Device-related complications, both "possibly," and "definitely" related, as well as serious adverse events will be summarized by reporting the total number of reported events by the number of operative cases. 11\. Study Monitoring Study monitoring will occur according to the Monitoring Plan set out specific to this study. The monitoring duties are to aid the Clinical Investigator in the production and maintenance of complete, legible, well-organized, and easily retrievable data. In addition, the Monitor will be responsible for ensuring the Clinical Investigators' understanding of the CIP and all applicable regulations. 12\. Good Clinical Practices (GCP) This investigation will be conducted in accordance with the principles of BS EN International Organization for Standardization (ISO) 14155:2020 titled "Clinical investigation of medical devices for human subjects" and International Council for Harmonisation (ICH) GCP (Good Clinical Practice) guidelines.
Study Type
OBSERVATIONAL
Enrollment
1,879
Knee Arthroplasty
Knee Arthroplasty
Knee Arthroplasty
Florida Orthopaedic Associates
DeLand, Florida, United States
Primary Objective
The objective of this study is to assess the safety and performance of Exactech Knee System devices. Data will be collected to provide objective evidence of safety and performance of Exactech Knee Systems used in primary knee arthroplasty. Data may be analyzed to support future presentations and publications of an Exactech Knee System and may be used to provide clinical evidence of the post market outcomes of Exactech Knee Systems to regulatory authorities when required. The following data will be collected: Demographics (e.g., height, weight, age, and gender), Preoperative information (e.g., indication for surgery, comorbidities, pre-surgical assessments of knee function), Operative details (e.g., intra-operative findings, surgical approach, length of surgery), Product information (components used in the knee surgery), Adverse events (e.g., infection, device failure, revision), Implant survivorship, \& Patient Reported Outcomes (KOOS, KSS, HSS, OKS and/or VAS)
Time frame: 10 Years
Secondary Objective
Collect radiographic data when available to examine radiographic outcomes. Analyze safety and performance of Exactech Knee System components when used in revision cases. Appropriate radiographs should be obtained to allow proper evaluation of the knee(s) by the investigator. The evaluation of the radiographs should be documented on the appropriate case report form for each applicable visit. 1. Radiographic views include: 1. AP View (weight bearing) 2. Lateral View 3. Patellar Skyline or Merchant View 2. Radiographic evaluations include: 1. Preoperative visit 2. Immediate postoperative visit 3. Post-operative follow-up visits 3. Radiographic assessments include: 1. Knee alignment 2. Patellofemoral evaluation 3. Radiolucent lines 4. Subsidence
Time frame: 10 Years