We designed a study to evaluate the impact of a two systematic strategies for PVI with the octaspline, balloon-based PFA (B-PFA) catheter. We hypothesized that the addition of electroanatomic guidance is non-superior to fluoroscopy-only guidance in achieving durable PVI.
Study design This is a single-center, randomized clinical study enrolling consecutive paroxysmal or persistent AF patients undergoing PVI with a B-PFA catheter (ClinicalTrials.gov identifier: pending). Patients will be randomized in a 1:1 basis to a fluoroscopy-only strategy vs. a strategy based on the same fluoroscopy workflow but with the addition of electroanatomic mapping (EAM). Procedures will be carried out under deep sedo-analgesia with propofol and fentanyl. Patients will be scheduled for systematic, invasive remapping of the left atrium (LA) and pulmonary veins (PVs) a minimum of 30 days after index ablation, regardless of recurrence status. The study will be carried out in University Hospital 12 de Octubre, a tertiary academic hospital, and has already received approval from the corresponding Institutional Review Board (code 23/208, mod. 2). Patient data will be handled according to the current General Data Protection Regulation 2016/679 of the European Parliament (EU-GDPR) and the Council of 27 April 2016 on Personal Data Protection as well as national and local regulations regarding patient autonomy, and rights and obligations in terms of information and clinical documentation. After a run-in phase of 10 cases per operator, 96 patients will be consecutively enrolled during a 4-month period (Figure 1). Randomization Patients who meet all eligibility criteria and provide informed consent will be assigned in a 1:1 ratio to one of two treatment arms: (1) PVI using fluoroscopy-only as guidance (control group) or (2) PVI guided by fluoroscopy with the addition of EAM (experimental group). Randomization will be performed electronically at each participating center via the Research Electronic Data Capture (REDCap®) platform (Vanderbilt University, Nashville, TN, USA). A computer-generated permuted block sequence, with stratification by AF presentation (paroxysmal or persistent), will be used to ensure balanced allocation. Study population Patients ≥18 years old, diagnosed with paroxysmal or persistent AF and clinical indication to undergo PVI will be included. Exclusion criteria are prior PVI or left atrial linear ablation, severe frailty or life expectancy \<1 year, unwillingness or inability to provide informed consent, ablation at sites beyond PVI or indication for additional electrophysiological study, contraindication or intolerance to heparin, presence of left atrial thrombus, congenital heart disease, and pregnancy, ongoing or planned in the following 6 months.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
DOUBLE
Enrollment
96
Pulsed field ablation for pulmonary vein isolation in atrial fibrillation ablation
University Hospital 12 de Octubre
Madrid, Madrid, Spain
RECRUITINGDurable PVI (per vein)
proportion of pulmonary veins durably isolated (i.e.: more than 30 days after index procedure);
Time frame: 30 days after index procedure
Durable PVI (per patient)
proportion of patients with all pulmonary veins durably isolated (i.e.: more than 30 days after index procedure);
Time frame: 30 days after index procedure
Fluoroscopy exposure
fluoroscopy time during index procedure
Time frame: At index procedure
PFA reversibility
area of reversible electroporation, measured by comparison between acute (after index procedure) and chronic (\>30 day after index procedure) left atrial remapping
Time frame: 30 days after index procedure