To assess the efficacy and safety of a percutaneous ablation strategy that targets multiple extrapulmonary structures as the Cox-Maze IV.
Persistent and long-standing atrial fibrillation (PsAF and LSAF) remain significant clinical challenges, particularly in patients with heart failure or high comorbidity burden, where the arrhythmia is often more sustained, complex, and resistant to conventional ablation approaches. Despite advancements in ablation technology, pulmonary vein isolation (PVI) alone has shown limited success in this subgroup. Current guidelines acknowledge the need for additional ablation targets beyond the pulmonary veins (PVs), yet evidence remains scarce and optimal strategies undefined. This single-arm, prospective pilot study investigates a novel ablation strategy that combines multi-target pulsed field ablation (PFA) with both endocardial intracavitary electrogram (EGM) mapping and non-invasive body surface mapping (BSM) to guide the identification and ablation of extra-PV atrial fibrillation drivers. This approach is designed to emulate the multilevel strategy of the surgical Cox-Maze IV, aiming for comprehensive arrhythmia substrate modification while minimizing procedural risk. The PFA+ADM protocol leverages recent advances in: * Pulsed Field Ablation (PFA): a non-thermal modality offering selective myocardial ablation with reduced risk to adjacent tissues (e.g., esophagus, phrenic nerve). * Non-invasive Driver Mapping (ADM): Electrocardiographic imaging (ECGi) with torso vests capable of reconstructing 3D epicardial activation patterns and identifying high-frequency or rotational driver sites. * Intracardiac Electrogram Analysis: High-resolution EGM signals captured during atrial fibrillation are analyzed to localize driver activity, complex fractionated atrial electrograms (CFAEs), or high dominant frequency regions. Study Workflow After informed consent, participants will undergo implantation of an insertable cardiac monitor (ICM) to allow for continuous AF burden tracking. The ablation procedure includes: 1. Baseline Electroanatomical Mapping: Creation of 3D maps of both atria using a high-density mapping catheter. 2. Non-invasive Driver Mapping: Performed using vest-based ECGi systems to non-invasively identify arrhythmogenic sources beyond the PVs. 3. Intracavitary Driver Mapping: Electrograms are analyzed for spectral content, including dominant frequency (DF) and organization index (OI), to confirm rotational or focal drivers. 4. Pulmonary Vein Isolation (PVI): Executed using PFA technology. 5. Targeted Extra-PV Ablation: Ablation of extrapulmonary targets guided by overlap between invasive and non-invasive driver maps. PFA will be used to eliminate identified high-frequency or rotational driver regions. 6. Post-ablation Re-mapping: Repeat non-invasive and invasive mapping to assess residual driver activity and efficacy of lesion sets. 7. Iterative Ablation (if necessary): Further lesion delivery at persistent driver sites, up to a clinically acceptable endpoint, defined as elimination or reduction in dominant frequency by at least 2 Hz or disappearance of driver behavior. 8. Follow-up Assessments: Clinical evaluations and ICM-based rhythm analysis at 3, 6, and 12 months. Technical Specifics and Rationale Rationale for Multitarget Approach: Atrial remodeling in patients with PsAF/LSPsAF is often diffuse and multifocal. Standard PVI addresses the initiating triggers of paroxysmal AF but fails to control perpetuating mechanisms in persistent forms. The multitarget strategy aims to: * Capture and eliminate active drivers that are not pulmonary in origin. * Address atrial regions exhibiting consistent high-frequency reentry. * Improve patient outcomes by personalizing ablation strategy based on individual driver distributions. Advantages of PFA Technology: PFA uses irreversible electroporation to ablate cardiomyocytes without significant collateral damage. This is especially relevant when targeting extrapulmonary sites near vulnerable structures (e.g., posterior wall near esophagus, Bachmann's bundle near the aorta). Additionally, PFA has demonstrated faster lesion creation and potentially shorter procedure times with comparable or superior efficacy in preclinical and early clinical data. Integration of ECGi and EGM-based Mapping: Simultaneous use of non-invasive ECG imaging and invasive mapping enables comprehensive localization of potential drivers, enhancing ablation precision. The goal is to improve arrhythmia control without significantly increasing procedural complexity or risk. Patient Profile and Unmet Needs: This trial targets patients often excluded or underrepresented in clinical trials-those with heart failure or multiple comorbidities who have higher recurrence rates post-ablation. These patients also tend to have more advanced atrial myopathy and may benefit from a more aggressive substrate modification strategy, if delivered safely. Data Handling and Interim Analysis Data will be collected prospectively, including electrogram recordings, ECGi maps, procedural data, imaging, and follow-up rhythm status. An interim analysis is planned after the first 25 patients to evaluate safety and refine the mapping-ablation workflow if necessary. Data from ICMs will be analyzed to calculate daily AF burden, detect arrhythmia recurrence, and correlate clinical outcomes with procedural findings. Safety is evaluated both acutely and in follow-up, with predefined thresholds for major complications (≤5%). The use of PFA is expected to significantly reduce thermal injury risks. Procedural metrics such as total duration, fluoroscopy time, and energy delivery time will also be recorded. This pilot study will serve as a foundation for larger multicenter trials by assessing the feasibility and clinical benefit of this precision-guided, multitarget ablation strategy in a high-risk AF population. Its results may help redefine ablation endpoints beyond pulmonary vein isolation and facilitate the integration of novel technologies into routine clinical practice.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
TREATMENT
Masking
NONE
Enrollment
50
* Informed consent gave by the patient. * Implantable loop recorder procedure * Clinical procedure starts * Electrophysiologycal study * Non-invasive map is obtained. * Electroanatomical map of both atria is generated. * Intracavitary electrogram (EGM) driver assessment * Pulmonary vein isolation * Extra pulmonary drivers ablation based on EGM findings (rotational and high frequency sites). * Non-invasive map is obtained to assess ablation impact on driver distribution. * Remap and extra pulmonary lesions are carried out until activity. At drivers sites disappears or decreases in at least 2 hertz or up to physician criteria. * Patient follow up
Hospital General Universitario Gregorio Marañon
Madrid, Madrid, Spain
RECRUITINGIncidence of Successful Pulmonary Vein Isolation and Freedom from Atrial Fibrillation or Reduction in Arrhythmia Burden
Success is defined as complete isolation of all pulmonary veins and either absence of atrial fibrillation recurrence or a significant reduction in arrhythmia burden over a 1-year follow-up period.
Time frame: 1 year
Incidence of Procedure-Related Complications, Including Mortality, Pulmonary Vein Stenosis, Nerve Injury, Stroke, and Major Bleeding Events [Safety]
The safety endpoint is defined as maintaining a complication rate of ≤5%, assessed by monitoring for acute and long-term complications such as mortality, pulmonary vein stenosis, nerve injury, stroke, bleeding, and other serious adverse events occurring within 30 days to 6 months post-procedure.
Time frame: 6 months
Percentage of patients in Per AF at the end of follow-up
Percentage of patients in Per AF at the end of follow-up.
Time frame: 1 year
Time to the first episode of atrial arrhythmia of more than 30 seconds
Time to the first episode of atrial arrhythmia of more than 30 seconds
Time frame: 1 year
Percentage of patients with AF/AT recurrence
Percentage of patients with AF/AT recurrence
Time frame: 1 year
Percentage of patients with <50% of AF/AT burden
Percentage of patients with \<50% of AF/AT burden
Time frame: 1 year
Left ventricular end-systolic volume at the end of follow-up
Physician assessment to measure the function parameters and ventricular size at the end of follow-up using ECHO or MRI. Left ventricular end-systolic volume at the end of 12-month follow-up. Units in mL.
Time frame: 1 year
Left ventricular end-diastolic volume at the end of follow-up
Physician assessment to measure the function parameters and ventricular size at the end of follow-up using ECHO or MRI. Left ventricular end-diastolic volume at the end of 12-month follow-up. Units in mL.
Time frame: 1 year
Left ventricular ejection fraction (LVEF) at the end of follow-up
Physician assessment to measure the function parameters and ventricular size at the end of follow-up using ECHO or MRI. Left ventricular ejection fraction (LVEF) at the end of 12-month follow-up. Units in percentage.
Time frame: 1 year
NYHA Functional Class at the end of follow-up
NYHA Functional Class at the end of follow-up
Time frame: 1 year
Adverse events of the procedures
Death, peripheral embolism, stroke, and plugging
Time frame: 1 year
Procedure duration/fluoroscopy time
Procedure duration/fluoroscopy time
Time frame: Measured on the day of the ablation procedure. No time frame.
Unplanned hospital admission for cardiovascular reasons
Unplanned hospital admission for cardiovascular reasons during the 12-month follow-up after the ablation procedure.
Time frame: 1 year
Unplanned hospital admission for any reason
Unplanned hospital admission for any reason during the 12-month follow-up after the ablation procedure.
Time frame: 1 year
New onset heart failure
New onset heart failure during the 12-month follow-up after the ablation procedure.
Time frame: 1 year
Worsening of functional class due to heart failure
Worsening of functional class due to heart failure during the 12-month follow-up after the ablation procedure.
Time frame: 1 year