Background: After surgery with general anesthesia, it is common for parts of the lungs to collapse, a condition called atelectasis. This can lead to low blood oxygen levels and other lung complications. Doctors use a setting on the breathing machine called PEEP (Positive End-Expiratory Pressure) to help keep the lungs open, but the best level to use is still debated. Purpose of the Study: The goal of this research is to find a PEEP level that minimizes the risk of lung collapse and low oxygen levels after surgery. The investigators will use lung ultrasound, a safe and non-invasive imaging method, to check the health of the lungs at the patient's bedside. The investigators will not assign treatments; they will observe the outcomes based on the PEEP level chosen by the patient's anesthesiologist during routine care. A simplified ultrasound scan will be used to score the amount of lung collapse before and after surgery. The main outcomes will be the frequency of lung collapse and the frequency of low oxygen levels (defined as SpO₂ of 90% or less).
Background and Rationale Postoperative pulmonary complications (PPCs) are a significant cause of morbidity and mortality, associated with a nearly 20% increase in lethality and prolonged hospital stays. The most common PPC is atelectasis, which can trigger more severe complications and develops in up to 90% of patients following the induction of general anesthesia. While computed tomography (CT) is the gold standard for diagnosing atelectasis, lung ultrasound (LUS) has emerged as a rapid, reliable, and validated bedside tool that is superior to standard chest radiography, with a high sensitivity (87.7%) and specificity (92.1%) compared to CT. A key strategy for preventing atelectasis is the application of positive end-expiratory pressure (PEEP). While ventilation with zero PEEP is considered harmful, the optimal level remains controversial. Large randomized trials (e.g., PROVHILO, PROBESE) have not shown a benefit for universally high PEEP strategies (e.g., 12 cm H₂O) and have noted an increased risk of hemodynamic instability. This contrasts with other studies suggesting benefits from moderate or individualized PEEP levels. This study designed to address this gap by analyzing data to identify a PEEP threshold associated with minimal atelectasis and desaturation, using a simplified LUS monitoring protocol. Study Objectives The primary objective of this study is to evaluate the effectiveness of a simplified LUS protocol for monitoring postoperative atelectasis and to determine a PEEP level associated with the minimum frequency and severity of atelectasis. Specific study tasks include: * To assess the frequency and severity of postoperative atelectasis in patients with different airway management strategies and PEEP levels. * To determine an optimal PEEP threshold for minimizing the risk of atelectasis and desaturation using ROC analysis. * To compare the rates of atelectasis and desaturation (SpO₂ ≤90%) between patient subgroups. * To conduct a multifactorial analysis of risk factors for developing postoperative atelectasis and desaturation. * To evaluate the prognostic value of the LUS score for predicting the risk of postoperative desaturation. Study Design and Methodology This is a single-center, retrospective cohort study conducted at the National Medical and Surgical Center n.a. N.I. Pirogov. The level of PEEP not assigned by the protocol but determined by the attending anesthesiologist as part of routine clinical practice. A simplified 2-zone LUS protocol will be used, focusing on the posterior-basal lung regions most susceptible to collapse. Lung aeration will be quantified using a 4-point scoring system (0-3), with 0 indicating normal aeration and 3 indicating major consolidation. Scans will be performed by one of three competent investigators before anesthesia and within the first hours after surgery, once the patient is fully awake.
Study Type
OBSERVATIONAL
Enrollment
450
Pirogov National Medical and Surgical Cente
Moscow, Russia
Frequency of Postoperative Atelectasis
The measure assesses the presence of postoperative atelectasis, defined as a lung ultrasound (LUS) score greater than 0. The assessment is conducted using a simplified 2-zone LUS protocol, with aeration evaluated on a 4-point scale (from 0 for normal aeration to 3 for major consolidation). The outcome is the percentage of patients who develop any degree of atelectasis (LUS score \> 0) following surgery
Time frame: The ultrasound measurement is performed within the first few hours after the completion of the surgical procedure
Frequency of Postoperative Desaturation
The percentage of patients who experience an episode of clinically significant postoperative desaturation. This is defined as a peripheral oxygen saturation (SpO₂) of 90% or less. The measurement is recorded after the patient is fully awake and breathing spontaneously
Time frame: Within the first few hours after completion of surgery
Severity of Postoperative Atelectasis Measured by Lung Ultrasound Score
The overall severity of postoperative atelectasis, measured by the total score from the lung ultrasound (LUS) assessment. The score is a quantitative value from 0 to 6 (up to 3 points for each of the two lung zones). This outcome is analyzed as a continuous variable, comparing the median scores between groups.
Time frame: The final LUS score is measured within the first few hours after completion of surgery