The VARIFY study is designed to find out how durable pulmonary vein isolation (PVI) is after treatment with the VARIPULSE pulsed field ablation (PFA) system in patients with paroxysmal atrial fibrillation (AF). AF is a common heart rhythm disorder caused by abnormal electrical signals coming from the pulmonary veins. In a PVI procedure, these veins are electrically isolated to prevent AF from recurring. Sometimes, the veins reconnect over time, which can lead to a return of arrhythmia. PFA is a new, non-thermal technology that uses short electrical pulses to safely and precisely treat heart tissue, reducing the risk of damage to nearby structures. The VARIPULSE system is one of these new PFA platforms. In this study, 20 adult patients with paroxysmal AF will undergo PVI using the VARIPULSE system. After 2-3 months, each patient will have a second planned procedure to check whether the pulmonary veins remain isolated. Any reconnections found will be treated immediately. The main goal is to determine how often the pulmonary veins stay durably isolated after the initial VARIPULSE treatment. Secondary goals include assessing the amount of scar tissue in the left atrium, recording any complications, and evaluating rhythm outcomes after one year. The results will help determine how effective and reliable the VARIPULSE system is for long-term treatment of AF.
Rationale: Pulmonary vein isolation (PVI) is the cornerstone of atrial fibrillation (AF) ablation. Pulmonary vein reconnection is associated with recurrence of arrhythmia, thus, durable PVI during the index procedure is important. Recently, pulsed field ablation (PFA) has emerged as a novel nonthermal energy source with high procedural safety and efficacy for PVI. Irreversible electroporation is achieved by the delivery of rapid, high-voltage pulsed electrical fields. Considering differences in catheter design and PFA protocols, it is important to establish PVI durability of the different PFA platforms. In the VARIFY study we will analyze PVI durability of the VARIPULSE platform in patients with paroxysmal AF using a 2-3 months protocol-mandated remapping study regardless of arrhythmia recurrence. Currently, there are no data on PVI durability of the VARIPULSE platform using mandatory remapping. Objective: To assess PVI durability in patients with paroxysmal AF who undergo a firsttime PVI with the VARIPULSE platform. Study design: Prospective, single-center study. Study population: Twenty consecutive adult patients (≥18 years old) with paroxysmal AF who are scheduled to undergo PVI with the VARIPULSE platform. Intervention: Patients will undergo a second invasive procedure 2-3 months after the index PVI. During the second procedure PVI durability will be assessed using high-definition mapping. Any reconnection will be targeted to achieve complete PVI. Main study parameters/endpoints: The primary outcome is the incidence of PV reconnection at the repeat procedure. The secondary outcome include the area of low voltage in the left atrium at the repeat procedure. Nature and extent of the burden and risks associated with participation, benefit, and group relatedness: All patients will undergo a repeat invasive procedure. This second procedure is associated with a similar procedural risk as the first procedure. A potential benefit of a mandated repeat procedure is that early pulmonary vein reconnection is identified and treated. Early treatment of pulmonary vein reconnection is associated with a better arrhythmia outcome.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
TREATMENT
Masking
NONE
Enrollment
20
Pulmonary vein isolation with the VariPulse catheter
Erasmus MC
Rotterdam, South Holland, Netherlands
RECRUITINGPercentage of pulmonary veins which shows reconnection during the repeat procedure 2-3 months after the index procedure
During the repeat procedure (2-3 months after the index procedure) the number of pulmonary veins which shows reconnection will be determined. The primary outcome measure is the percentage of pulmonary veins with reconnection.
Time frame: PV reconnection will be determined in the period from 2 to 3 months after the index procedure.
Extent of low voltage area in the left atrium identified at the repeat procedure 2-3 months after the index procedure
The low voltage area (\<0.5 mV) in the left atrium will be identified during the repeat procedure using high-density 3D-mapping with the OCTARAY catheter.
Time frame: Low voltage area will be determined in the period from 2 to 3 months after the index procedure.
One-year freedom from atrial arrhythmia after a blanking period of 3 months.
Recurrence of any atrial arrhythmia will be defined as the documentation of atrial arrhythmia on a standard 12-lead ECG or the documentation of ≥30 seconds of atrial arrhythmia on a Holter after a blanking period of 3 months. Twenty-four Holter monitoring will be performed at 6 and 12 months after the ablation procedure.
Time frame: From 3 to 12 months after the index procedure.
Percentage of patients with a procedure-related complication
All procedure-related complications will be identified from the index procedure till the 1-year follow-up visit.
Time frame: From the index procedure till the 1-year follow-up visit.