Introduction: Pre-hepatic portal hypertension of malignant origin can lead to severe complications such as refractory ascites or gastrointestinal bleeding, significantly impairing patients' quality of life. Available therapeutic options are mainly symptomatic and do not address the venous obstruction. Portal vein stenting represents a minimally invasive alternative, which remains poorly studied in this setting. The aim of our study was to evaluate portal stent patency, as well as clinical efficacy and safety, in patients with symptomatic malignant stenosis or occlusion of the portal system. Methods: The team conducted a retrospective cohort study including 63 consecutive patients treated between April 2004 and March 2024 at CHU l'Archet and CAL Nice for symptomatic malignant stenosis or occlusion of the portal system. All patients underwent percutaneous transhepatic portal vein stenting with uncovered self-expandable metallic stents. The primary endpoint was stent patency, defined as the interval between implantation and the occurrence of an occlusion confirmed by imaging or end of follow-up. Secondary endpoints included technical success, clinical success (improvement of portal hypertension signs), and the occurrence of adverse events, graded according to the 2017 SIR classification.
Study Type
OBSERVATIONAL
Enrollment
63
The intervention consisted of percutaneous transhepatic implantation of a self-expanding metallic stent in the portal vein to treat malignant symptomatic portal vein stenosis or occlusion. Patients were selected on the basis of clinical complications related to portal hypertension, such as refractory ascites or gastrointestinal bleeding. The procedure aimed to restore portal vein patency and reduce symptoms. Stents of different lengths (40 mm, 60 mm, or 80 mm) were deployed depending on the anatomical extent of the obstruction. All procedures were performed by interventional radiologists under image guidance. Patients were subsequently followed for technical success, stent patency, clinical efficacy, and procedure-related safety.
CHU de NICE
Nice, Alpes Maritimes, France
Portal vein stent patency.
Stent patency was assessed using cross-sectional imaging and/or Doppler ultrasound.
Time frame: From stent placement until death or loss to follow-up to 110 months.
Clinical efficacy (physiological parameter) of portal vein stenting
Assessment was performed retrospectively using medical records, imaging studies, and follow-up endoscopy when available.
Time frame: From stent placement until death or loss to follow-up to 110 months.
Safety of portal vein stenting.
Procedure-related adverse events were retrospectively collected from medical records and classified according to the Society of Interventional Radiology (SIR) complication grading system. Safety was assessed by recording the occurrence, type, and severity of adverse events following stent placement.
Time frame: From procedure date until last follow-up to 110 months and graded according to SIR 2017 classification
Technical success
Successful stent implantation was defined as placement at the intended anatomical site with confirmed patency on completion portography.
Time frame: From stent placement start to completion portography (1 hour).