Ancillary study of the PregMouv study which aims to evaluate an intervention allowing the best adherence of women in terms of physical activity. Several types of interventions are therefore planned in this study: no intervention, physical activity sessions in person, by videoconference or mixed (in person and videoconference) with accelerometer assessment of the level of physical activity practiced (in the form of energy expenditure, in MET). Thus, for our ancillary study, a comparison of the cardiac variability of newborns will be carried out according to the level of physical activity practiced by the mother regardless of the intervention she benefited from within the framework of the PregMouv study. A comparison of the average saturation and the time spent below 90% saturation will be carried out via a continuous recording of saturation by oximetry. A longitudinal follow-up for the assessment of height and weight growth (from growth curves) and neurodevelopment (by clinical examination and self-questionnaire) is also planned until the child is 2 years old.
Holter ECG and oximetry recording of the newborn for a minimum of 6 hours during their stay in the maternity ward, or in another perinatal sector. Evaluation at the child's 2nd birthday by collecting the height-weight curve, the 2nd birthday clinical examination and self-questionnaire, ASQ, from the parents. Blind interpretation and analysis of the results. Comparison of the results according to the mothers' level of physical activity (in MET/min/week), assessed by the accelerometer study at T2 and T3 of pregnancy. Search for correlation between the level of physical activity practiced and the child's physiological parameters.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
DIAGNOSTIC
Masking
NONE
Enrollment
100
A Holter ECG recording will be performed on the child's second night for a minimum of 6 hours.
Oximetry recording will be performed on the child's second night for a minimum of 6 hours.
CHU de Clermont-Ferrand
Clermont-Ferrand, France
RECRUITINGHeart rate variability
Is measured by SDNN (standard deviation of all normal R-R intervals), a reflection of the variability of the global autonomic nervous system of newborns, obtained from a Holter ECG recording.
Time frame: during the child's second night.
Heart rate variability
Others parameters of heart rate variabilt obtained from a Holter ECG recording by RMSSD (root mean square of differences of successive RR intervals)
Time frame: during the child's second night
Heart rate variability
Others parameters of heart rate variabilt obtained from a Holter ECG recording by NN50 (number of RR intervals that differ by \> 50 ms)
Time frame: during the child's second night
Heart rate variability
Others parameters of heart rate variabilt obtained from a Holter ECG recording by p NN50 (percentage of consecutive RR intervals that differ by \>50 ms)
Time frame: during the child's second night
Heart rate variability
Others parameters of heart rate variabilt obtained from a Holter ECG recording by SD1 (standard deviation 1)
Time frame: during the child's second night
Heart rate variability
Others parameters of heart rate variabilt obtained from a Holter ECG recording by and HF (high frequency power)
Time frame: during the child's second night
Heart rate variability
Others parameters of heart rate variabilt obtained from a Holter ECG recording by SD2 (standard deviation 2)
Time frame: during the child's second night
Heart rate variability
Others parameters of heart rate variabilt obtained from a Holter ECG recording by SD1/SD2 ratio
Time frame: during the child's second night
Heart rate variability
Others parameters of heart rate variabilt obtained from a Holter ECG recording by LF (low frequency)
Time frame: during the child's second night
Respiratory function
Assessed by oximetry: desaturation index and drop per hour of more than 3%.
Time frame: During the child's second night
Respiratory function
Assessed by oximetry: time spent below 90%, 80% and 70% saturation (in raw value and in two classes depending on whether the value is greater than or equal to 5)
Time frame: During the child's second night
Respiratory function
Assessed by oximetry: mean saturation (in raw value and in two classes depending on whether the value is strictly less than 93)
Time frame: During the child's second night
Height growth
height measurement in centimeters
Time frame: at 2 years old
weight growth
weight measurement in kilograms
Time frame: at 2 years old
neurodevelopment
assessed by the Ages \& Stages Questionnaires, Third Edition (ASQ-3)
Time frame: at 24 months
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.