This research protocol focuses on the pre- and post-operative evaluation of ICP using non-invasive methods, particularly in the context of surgery for brain tumor removal. By utilizing ocular ultrasound to measure ONSD and ONSD/ETD ratios, this study hypothesizes that the utility of these parameters in monitoring ICP pre- and post-operative periods could be effective.
This research protocol focuses on the pre- and post-operative evaluation of ICP using non-invasive methods, particularly in the context of brain tumor resection surgery. By utilizing ocular ultrasound to measure ONSD and ONSD/ETD ratios, this study hypothesizes that the utility of these parameters in monitoring ICP pre- and post-operative periods could be effective. This study aims to evaluate the effectiveness of the ONSD and the ONSD/ETD ratio using ultrasound as a non-invasive method for measuring intracranial pressure pre- and post-operatively in brain tumor patients.
Study Type
OBSERVATIONAL
Enrollment
60
The examination will employ an ultrasound machine with a linear probe. Patients will be positioned supine with their heads elevated at a 20-30° angle. They will be instructed to keep their eyes closed in a neutral position while suppressing voluntary eye movement.The transducer will be gently placed on the gel in the temporal region of the eyelid to avoid exerting pressure on the eye. Optic nerve sheath diameter will be measured 3 mm posterior to the optic nerve's tip, with electronic calipers used to measure the values. ONSD will be defined as the distance within the dura mater, and ETD will be measured across the maximal transverse diameter of the eyeball, from one side of the retina behind the lens to the other. Measurements will be taken in both coronal and sagittal planes by positioning the probe perpendicular (90°) to the coronal plane, ensuring optimal alignment of the optic nerve with the probe.
Faculty of medicine, Tanta university
Tanta, El Gharbyia, Egypt
optic nerve sheath diameter dynamics
the measuremnt of optic nerve sheath diameter and optic nerve sheath diameter to transverse eyeball diamter ratio
Time frame: before (in the preoperative holding area) and after the surgery (immediate, 1,2, 4, 6, and 12 hr in ICU).
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.