This study is designed to compare two methods for performing a nasal endoscopic examination used in the evaluation of excessive watering or tearing of the eyes. The purpose of the study is to determine whether a new, smaller, modified camera system can produce images of the inside of the nose that are as clear and useful as those produced by the standard endoscopic camera system currently used in clinics. The study seeks to answer the question of whether a compact, easy-to-store camera system can provide similar diagnostic image quality to the traditional, larger tower-based system. The clinical steps of the nasal examination remain the same; the only difference is the type of camera system used to capture the images.
This study evaluates two imaging systems used during routine nasal endoscopy performed for assessment of epiphora and related nasolacrimal or sinonasal concerns. The protocol involves conducting a standard nasal endoscopic examination with the conventional full-size tower-mounted camera system typically utilized in ophthalmology and otolaryngology outpatient settings, followed by a second examination using a modified compact camera system. Both examinations use the same endoscope and follow identical clinical steps. The modified camera system attaches at the usual hand-position point on the endoscope and is designed to reduce equipment footprint, increase portability, and simplify storage. The second examination adds an estimated 3-5 minutes to the clinical encounter and does not introduce additional maneuvers or diagnostic procedures. The primary objective is to compare image quality between the standard system and the compact system. Secondary objectives include assessments of device usability, handling characteristics, and overall feasibility of integrating the compact system into routine clinical workflow. This evaluation aims to determine whether the compact camera system can provide imaging performance comparable to the traditional tower-based system while offering potential operational benefits. These benefits may include improved flexibility in space-constrained environments, reduced dependence on fixed equipment, and expanded opportunities for nasal endoscopy in clinics with limited infrastructure. Findings may inform future decisions regarding endoscopic equipment selection across various clinical settings.
Study Type
OBSERVATIONAL
Enrollment
40
The Sony Action Camera was modified to allow direct coupling with a standard rigid nasal endoscope: 1. The native 180° wide-angle lens was replaced with a narrow-field 31° lens, enabling full-frame capture of the endoscopic image without peripheral distortion. 2. The camera housing was adapted by attaching a ¾-inch water pipe end connector, serving as a secure and stable mount for the endoscope eyepiece. The modified system captures both video and still images.
University of Arkansas for Medical Sciences
Little Rock, Arkansas, United States
RECRUITINGImage Quality Score of Modified Portable Endoscopic Camera System
Image quality of the modified portable endoscopic camera system will be evaluated using a 5-point Likert scale assessing resolution, clarity of anatomical structures, and overall clinical utility. Three attending physicians will independently grade anonymized images from each nasal anatomical site. Scores will be compared with those obtained from the standard endoscopic tower.
Time frame: Grading completed within 3 months of enrollment completion.
Image Quality Score of Standard Endoscopic Tower System
Image quality of the standard endoscopic tower will be evaluated using the same 5-point Likert grading scale and process applied to the modified system. These scores will serve as the comparator for paired analysis.
Time frame: Grading completed within 3 months of enrollment completion.