The aim of the study is to investigate the effects of thoracic spinal manipulation on balance, fall risk, and thoracic mobility of the patients with chronic stroke.
The study, utilizing a randomized crossover design, is planned to be conducted on a minimum of 26 patients with stroke who meet the inclusion and exclusion criteria. Patients included in the study will be randomly assigned to receive both placebo thoracic spinal manipulation and thoracic spinal manipulation interventions.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
DOUBLE
Enrollment
60
This technique is based on the application of a high-velocity, low-amplitude force to the thoracic spine with the aim of increasing thoracic mobility.
This intervention is a classic method used to evaluate the effect of thoracic spinal manipulation.
Bolu İzzet Baysal Fizik Tedavi ve Rehabilitasyon Eğitim ve Araştırma Hastanesi
Bolu, Merkez, Turkey (Türkiye)
Overall Postural Stability Index Measurement
This index will be assessed by measuring deviations of the center of gravity in the anteroposterior and mediolateral directions. Lower scores indicate smaller deviations and better postural stability. The test will be performed on a stable platform with two trials of 30 seconds each. The average of the three trials will be automatically calculated by the TechnoBody balance system.
Time frame: Change from baseline overall postural stability index immediately after the intervention
Fall Risk Assessment
Fall risk will be assessed by measuring the patient's ability to maintain balance on an unstable platform. Based on their ability to maintain balance, a fall risk score will be generated, with higher scores indicating a greater risk of falling. The test will be performed with two 30-second trials. The average of the three trials will be calculated automatically by the TechnoBody balance system.
Time frame: Change from baseline overall postural stability index immediately after the intervention
Anteroposterior Stability Index Measurement
The anteroposterior stability index will be assessed by measuring deviations of the center of gravity in the anteroposterior direction. Lower scores indicate smaller deviations and better anteroposterior postural stability. The test will be performed on a stable platform with two trials of 30 seconds each. The average of the three trials will be automatically calculated by the TechnoBody balance system.
Time frame: Change from baseline overall postural stability index immediately after the intervention
Mediolateral Stability Index Measurement
The mediolateral stability index will be assessed by measuring deviations of the center of gravity in the mediolateral direction. Lower scores indicate smaller deviations and better mediolateral postural stability. The test will be performed on a stable platform with two trials of 30 seconds each. The average of the three trials will be automatically calculated by the TechnoBody balance system.
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Time frame: Change from baseline mediolateral stability index immediately after the intervention
Thoracic Mobility
Thoracic mobility will be assessed by measuring trunk rotation and lateral flexion using a smartphone inclinometer positioned at the level of T2.
Time frame: Change from baseline mediolateral stability index immediately after the intervention