Purpose: The primary goal of this study is to investigate how different levels of upper extremity (arm) support affect walking patterns in individuals who have experienced a stroke. Specifically, the research aims to determine how restricting or facilitating arm swing during walking modulates spatiotemporal gait parameters (such as speed, step length, and rhythm). Background: Arm swing plays a crucial role in maintaining balance, stability, and energy efficiency during normal walking. Following a stroke, many patients use walking aids (like canes or walkers) or clinical supports (like parallel bars) that restrict natural arm movement. This study examines whether these restrictions significantly alter gait mechanics in the stroke population. Methodology: Participants will participate in a cross-over experimental trial. Each participant will walk on a specialized treadmill system (C-Mill VR+) under three randomized conditions: 1. Unsupported walking (no arm support), 2. Single-arm support (using the non-paretic side), 3. Dual-arm support (using both arms). Researchers will record gait speed, step length, cadence, and duration of stance/swing phases for each condition. Expected Outcome: The findings will provide scientific evidence on how different support strategies modulate walking performance. This information will help physical therapists design more effective, individualized rehabilitation programs to improve mobility and quality of life for stroke survivors.
Study Setting and Population: This study will be conducted at the Ankara Bilkent City Hospital, Physical Therapy and Rehabilitation Hospital. The study population consists of patients receiving treatment for hemiplegia (ICD-10 G.81) due to stroke. Procedural Overview: Following the initial clinical and demographic assessment (including MoCA, FAC, and Brunnstrom staging), participants will undergo gait analysis under three distinct conditions: Unsupported walking, Single-arm support (using the non-paretic side), Dual-arm support Randomization and Bias Control: To eliminate order and carry-over effects, the sequence of the walking conditions will be randomized and balanced using a predefined table (e.g., ABC, BCA, CAB). While the first condition will be the one the patient feels most comfortable with, the subsequent two conditions will be assigned randomly. Gait Analysis Protocol: Acclimatization: Before data collection, a 2-minute familiarization walk will be provided for each condition. Measurement: Spatiotemporal gait data will be recorded for 2 minutes using the C-Mill VR+ system, which utilizes a force-plate integrated treadmill (100 cm x 240 cm) with a 500 Hz sampling frequency. Safety and Fatigue Management: To prevent fatigue, a minimum rest period of 2 minutes will be provided between trials. The rest period will be extended if the participant's perceived exertion (Borg RPE) exceeds 10. A physiotherapist will accompany the participant throughout the test to ensure safety and prevent falls. Standardization: Participants will wear comfortable athletic shoes. If the participant uses an Ankle-Foot Orthosis (AFO) or other orthotics, these will be maintained consistently across all three walking conditions.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
BASIC_SCIENCE
Masking
NONE
Enrollment
34
Description: A treadmill system equipped with integrated force plates and augmented reality (VR) capabilities. It records spatiotemporal gait data at a 500 Hz sampling frequency. In this study, the device is used to measure gait parameters under different upper extremity support conditions.
The standardized protocol of walking under no support: Natural walking with free arm swing. Each trial lasts 2 minutes with mandatory rest periods to prevent fatigue.
The standardized protocol of walking under unilateral support: Holding the handrail with the non-paretic hand. Each trial lasts 2 minutes with mandatory rest periods to prevent fatigue.
The standardized protocol of walking under bilateral support: Holding the handrails with both hands. Each trial lasts 2 minutes with mandatory rest periods to prevent fatigue.
Ankara Bilkent City Hospital
Ankara, Turkey (Türkiye)
RECRUITINGCadence
Data will be collected using the C-Mill VR+ force-plate integrated treadmill system at a sampling frequency of 500 Hz. These parameters will be used to compare the biomechanical differences between unsupported, single-arm, and dual-arm supported walking.
Time frame: At the end of each 2-minute walking condition during the single study session.
Stride length
Data will be collected using the C-Mill VR+ force-plate integrated treadmill system at a sampling frequency of 500 Hz. These parameters will be used to compare the biomechanical differences between unsupported, single-arm, and dual-arm supported walking.
Time frame: At the end of each 2-minute walking condition during the single study session.
Double Support Time
Data will be collected using the C-Mill VR+ force-plate integrated treadmill system at a sampling frequency of 500 Hz. These parameters will be used to compare the biomechanical differences between unsupported, single-arm, and dual-arm supported walking.
Time frame: At the end of each 2-minute walking condition during the single study session.
Functional Walking Speed (10-Meter Walk Test)
The 10-Meter Walk Test (10MWT) will be used to assess the patient's functional walking speed. The time taken to walk the middle 10 meters of a 14-meter path at a comfortable pace will be recorded in seconds and converted to kilometers per hour (km/h).
Time frame: Baseline (at the beginning of the study session).
Functional Ambulation Category (FAC)
A 6-point scale (0-5) used to assess the level of physical support required by the patient during walking. 0 indicates the patient cannot walk or requires help from 2 people; 5 indicates the patient can walk independently anywhere.
Time frame: Baseline (at the beginning of the study session).
Hemiplegic Side Step Length
Data will be collected using the C-Mill VR+ force-plate integrated treadmill system at a sampling frequency of 500 Hz. These parameters will be used to compare the biomechanical differences between unsupported, single-arm, and dual-arm supported walking.
Time frame: At the end of each 2-minute walking condition during the single study session.
Hemiplegic Stance Time
Data will be collected using the C-Mill VR+ force-plate integrated treadmill system at a sampling frequency of 500 Hz. These parameters will be used to compare the biomechanical differences between unsupported, single-arm, and dual-arm supported walking.
Time frame: At the end of each 2-minute walking condition during the single study session.
Non-Hemiplegic Stance Time
Data will be collected using the C-Mill VR+ force-plate integrated treadmill system at a sampling frequency of 500 Hz. These parameters will be used to compare the biomechanical differences between unsupported, single-arm, and dual-arm supported walking.
Time frame: At the end of each 2-minute walking condition during the single study session.
Non-Hemiplegic Step Length
Data will be collected using the C-Mill VR+ force-plate integrated treadmill system at a sampling frequency of 500 Hz. These parameters will be used to compare the biomechanical differences between unsupported, single-arm, and dual-arm supported walking.
Time frame: At the end of each 2-minute walking condition during the single study session.