The goal of this clinical trial is to confirm the safety and feasibility of robotic telesurgery when used for the surgical management of prostate cancer in participates undergoing treatment for prostate cancer. In this clinical trial, participants will receive robotic telesurgery treatment for prostate cancer.
Robotic surgery began in the early 2000s and has been increasingly considered the preferred surgical approach for various urological surgeries. Urologists were among the first doctors to adopt this technology, and today, robotic surgery is included in many medical guidelines as a main treatment option for localized urological cancers. As robotic systems become more widely available and continue to improve, many new treatment options have been developed in the field of urologic cancer care. These advances offer the benefit of less invasive surgery. However, having more complex surgical options can also create challenges. Access to highly trained surgeons and specialized treatments may be limited to large academic or major medical centers, making it harder for some people to receive this care. Telesurgery has been introduced as a way to make the process of robotic surgical care more accessible. Telesurgery is defined as the completion of a robotic surgical procedure by a remote surgeon that is located distant to the person receiving surgery. Although telesurgery was first described by researchers in 2001, the widespread adoption of telesurgery is limited by the availability of surgical technology, reliable and secure high-speed network infrastructure, and regulatory constraints. In addition to the robotic console and participant cart required for the standard robotic procedures, telesurgery also requires an additional robotic console for the remote surgeon that mimics the functionality of the primary console. In addition, separate network tests using phantom models constituted mandatory preparation prior to the actual procedure to ensure a reliable, low-latency network infrastructure. Preliminary studies have reported on the safety of robotic telesurgery. Most of these studies involve using telesurgery for the management of localized prostate cancer. However, these studies are limited by small sample sizes, heterogeneous study design, robotic surgical platform, and clinical practices. Furthermore, there remains a lack of consensus on best practice guidelines on robotic telesurgery, particularly involving the network requirements, ethical considerations, and intraoperative requirements. This study aims to confirm the safety and feasibility of robotic telesurgery when used for the surgical management of prostate cancer.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
TREATMENT
Masking
NONE
Participants will receive surgery using the High-Intensity Focused Ultrasound (HIFU) robotic device, using the existing, secured network as part of the Cleveland Clinic infrastructure, to deliver focal ablative treatment for prostate cancer.
Case Comprehensive Cancer Center, Cleveland Clinic Foundation Glickman Urological Institute
Cleveland, Ohio, United States
Surgical success rate
Surgical success rate is defined as the procedure not requiring any conversion, without any evidence of perioperative complications. Conversion was defined as the switch from the intended surgery to other surgical techniques and/or modalities. Surgical complications of interest included major complications defined as those scoring grades 3a and above according to the Clavien-Dindo classification systems.
Time frame: Day 1 (up to 90 days)
Total operative time (minutes)
Total operative time will be measured in minutes on the day of surgery.
Time frame: Day 1 (up to 90 days)
Total robotic console time (minutes)
Total robotic console time is the amount of time that the robotic console is in use during surgery and will be measured in minutes on the day of surgery.
Time frame: Day 1 (up to 90 days)
Distance between the two institutions (miles)
The distance between two institutions refers to the distance between the surgeon console operated by the remote surgeon and the robotic patient cart where the patient is located. If these are at two different institutions, distance between institutions will be measured in miles.
Time frame: Day 1 (up to 90 days)
Round-trip latency time (milliseconds)
Round-trip latency time is defined as the total time delay between an action initiation on the robotic console and that corresponding action being carried out. Round-trip latency time is measured in milliseconds (ms).
Time frame: Day 1 (up to 90 days)
Intraoperative blood loss (milliliters (mL))
Intraoperative blood loss will be measured in milliliters (mL) on the day of surgery.
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Time frame: Day 1 (up to 90 days)
Conversion from remote to in-house surgeon
Conversion from remote to in-house surgeon occurs when the network latency exceeds 300 milliseconds (ms). This will be measured as number of instances of conversion.
Time frame: Day 1 (up to 90 days)
Conversion from planned surgery to other techniques
Conversion will be measured as number of instances of conversion from planned surgery to other techniques, at the discretion of the surgeon.
Time frame: Day 1 (up to 90 days)
Conversion from one robotic surgical system to another
Conversion will be measured as number of instances of conversion from the planned robotic surgical system to other backup surgical systems, at the discretion of the surgeon.
Time frame: Day 1 (up to 90 days)
Intraoperative complications
Intraoperative complications will be measured as the number of instances of complications.
Time frame: Day 1 (up to 90 days)
Evidence of intraoperative network interruptions
Intraoperative network interruptions include those pertaining to the robotic procedure, including interruptions to the audiovisual feed, and this will be measured as number of instances of interruptions.
Time frame: Day 1 (up to 90 days)
Evidence of intraoperative device malfunctions
This will be measured as the number of instances of device malfunctions during surgery.
Time frame: Day 1 (up to 90 days)
Postoperative hospital length of stay (hours)
Postoperative hospital length of stay will be measured in hours.
Time frame: Up to Day 90
Postoperative complications
Postoperative complications will be measured as the number of instances of complications.
Time frame: Up to Day 90
Hospital readmission within 90 days of surgery
Hospital readmissions will be measured as number of instances of readmissions.
Time frame: Up to Day 90