This is a prospective, non-randomized, observational cohort study conducted at the FSBI "NMRC TPM" of the Ministry of Healthcare of the Russian Federation. Left atrial appendage closure (LAAC) has been shown to be non-inferior to oral anticoagulation for preventing cardioembolic events in patients with atrial fibrillation. However, the optimal post-procedural antithrombotic regimen following LAAC remains unclear, with no consensus on evidence-based therapy. Given current trends in cardiology favoring reduced-intensity antithrombotic strategies, this study aims to contribute to the evidence base by evaluating whether LAAC followed by reduced-dose apixaban (2.5 mg BID) for 3 months with subsequent complete withdrawal of antithrombotic therapy is superior to long-term standard-dose DOAC therapy in patients with non-valvular atrial fibrillation.
This is a prospective, non-randomized, observational cohort study enrolling patients with non-valvular atrial fibrillation (NVAF). Participants will be assigned to one of two groups based on clinical indication. LAAC group: Patients with NVAF undergoing left atrial appendage closure (LAAC) who will receive reduced-dose apixaban (2.5 mg BID) for 3 months, followed by complete withdrawal of antithrombotic therapy. The criterion for anticoagulation discontinuation will be a satisfactory result on transesophageal echocardiography (TEE) or cardiac computed tomography (CT) at 3 months post-implantation, confirming adequate device sealing without significant peri-device leak or device-related thrombosis. Participants will undergo additional TEE or cardiac CT at 6 and 12 months after the procedure and will be followed up by telephone at 18, 24, 30, and 36 months after enrollment. Control group: Patients with NVAF indicated for long-term oral anticoagulation will receive standard full-dose direct oral anticoagulant (DOAC) therapy. Participants in the control group will be followed up by telephone at 3, 6, 12, 18, 24, 30, and 36 months after enrollment. Observation period: 36 months. Devices used for LAAC will include the Watchman FLX (Boston Scientific, St. Paul, Minnesota, USA) and the Amplatzer Amulet (Abbott, St. Paul, Minnesota, USA). Primary endpoint: A composite of major bleeding (BARC type ≥3), all-cause mortality, ischemic stroke, systemic embolism, device-related thrombosis (DRT), and significant peri-device leak over 36 months of follow-up. Secondary endpoints: Individual components of the primary composite endpoint over 36 months of follow-up. Propensity score matching will be used to create balanced comparison groups for statistical analysis, adjusting for baseline differences between cohorts.
Study Type
OBSERVATIONAL
Enrollment
464
Percutaneous left atrial appendage closure using Watchman FLX (Boston Scientific) or Amplatzer Amulet (Abbott) devices
Reduced-dose apixaban 2.5 mg BID for 3 months post-LAAC, followed by complete withdrawal of antithrombotic therapy
Standard-dose DOAC therapy (e.g., apixaban 5 mg BID, rivaroxaban 20 mg daily, or other DOAC per physician discretion) continued for the duration of follow-up
Federal State Budgetary Institution National Medical Research Center for Therapy and Preventive Medicine of the Ministry of Healthсare of the Russian Federation
Moscow, Russia
RECRUITINGComposite of major adverse events
Composite endpoint including: bleeding events (BARC type ≥3), all-cause death, ischemic stroke, systemic embolism, device-related thrombosis (DRT), and peri-device leak (\>3 mm)
Time frame: 36 months from enrollment
Major bleeding events
Incidence of bleeding events classified as BARC type 3 or higher
Time frame: 36 months from enrollment
All-cause mortality
Incidence of death from any cause
Time frame: 36 months from enrollment
Ischemic stroke
Incidence of ischemic cerebrovascular events confirmed by imaging
Time frame: 36 months from enrollment
Systemic embolism
Incidence of systemic embolic events excluding stroke
Time frame: 36 months from enrollment
Device-related thrombosis
Incidence of thrombus formation on the LAAC device detected by imaging (LAAC group only)
Time frame: 36 months from enrollment
Peri-device leak
Incidence of peri-device leak \>3 mm detected by transesophageal echocardiography or cardiac CT (LAAC group only)
Time frame: 36 months from enrollment
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.