Obstructive sleep apnea (OSA) is a common condition in which the airway repeatedly collapses during sleep, leading to poor sleep quality and reduced oxygen levels. Hypoglossal nerve stimulation (HGNS) is an approved treatment that uses a small implanted device to stimulate the genioglossus muscle and keep the airway open. However, some patients continue to have OSA despite using HGNS. Atomoxetine and oxybutynin, "AtoOxy", is a promising pharmacologcal therapy under investigation that has been shown to activate pharyngeal muscles-in particular non-genioglossus muscles--but appears more efficacious in some patients than others. This study will test whether the combination of AtoOxy and HGNS can further improve breathing during sleep compared to either monotherapy alone. Participants with OSA and an HGNS device will be randomized to receive, in random order: HGNS+AtoOxy, HGNS alone (plus placebo), AtoOxy alone (HGNS device off), and placebo (HGNS device off), in a cross-over trial. The main goal is to determine whether the combined treatment reduces the number of breathing events during sleep; the primary outcome test will compare HGNS+AtoOxy versus HGNS alone. The effect of each intervention versus placebo will also be presented. The study will also examine how individual patient characteristics influence response to treatment.
Residual obstructive sleep apnea (OSA) is common among patients treated with hypoglossal nerve stimulation (HGNS), reflecting incomplete correction of underlying pathophysiological traits. In addition to upper airway collapsibility, non-anatomical factors such as a low arousal threshold may contribute to persistent disease despite HGNS therapy. Pharmacologic modulation of these traits represents a potential strategy to enhance treatment efficacy. Atomoxetine (a norepinephrine re-uptake inhibitor) and oxybutynin (an anti-muscarinic agent) have been shown to increase upper airway muscle tone and raise the arousal threshold, leading to reductions in OSA severity in prior studies. However, their combined effect when added to ongoing HGNS therapy has not been systematically evaluated. This study is a randomized, placebo-controlled, crossover trial designed to assess the acute effects of combined pharmacologic and electrical stimulation on OSA severity. Participants with OSA who are already implanted with HGNS, or pending clinical implantation, will be enrolled in a four-period randomized placebo-controlled cross-over trial assessing HGNS+AtoOxy, HGNS alone (plus placebo), AtoOxy alone (HGNS device off), and placebo (HGNS device off). The main goal is to determine whether the combined treatment reduces the number of breathing events during sleep; the primary outcome test will compare HGNS+AtoOxy versus HGNS alone. The effect of each intervention versus placebo will also be presented. Polysomnographic measurements will be also be used to explore mechanisms underlying response, including the interaction between pharmacologically modifiable traits and HGNS-mediated airway stabilization. Additional analyses will evaluate whether baseline physiological characteristics predict treatment response, with the goal of informing personalized treatment strategies for patients with residual OSA. Patient-reported outcomes, including sleepiness, sleep-related quality of life, fatigue, and treatment satisfaction, will also be assessed to evaluate the broader clinical impact of the combination intervention.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
TRIPLE
Enrollment
24
Electrical stimulation of the hypoglossal nerve using an implanted device (Inspire Medical Systems) to activate upper airway dilator muscles during sleep at prescribed therapeutic settings. Atomoxetine 80 mg administered orally at bedtime. Oxybutynin 5 mg administered orally at bedtime. Dose escalation with half-dose for initial 3 nights followed by full dose.
Electrical stimulation of the hypoglossal nerve using an implanted device (Inspire Medical Systems) to activate upper airway dilator muscles during sleep at prescribed therapeutic settings. Matching placebo capsules administered orally at bedtime.
Atomoxetine 80 mg administered orally at bedtime. Oxybutynin 5 mg administered orally at bedtime. Dose escalation with half-dose for initial 3 nights followed by full dose. HGNS device off
Matching placebo capsules administered orally at bedtime. HGNS device off
Brigham and Women's Hospital
Boston, Massachusetts, United States
RECRUITINGApnea-Hypopnea Index
Apnea-hypopnea index (AHI), defined as the number of apneas and hypopneas per hour of sleep, measured by overnight polysomnography at the end of each treatment period. Quantitative outcome variable: percent change (symmetrized) from baseline.
Time frame: 2 Weeks
Hypoxic Burden
Hypoxic burden, defined as the area under the oxygen desaturation curve associated with respiratory events multiplied by event frequency, measured during overnight polysomnography. Quantitative outcome variable: percent change (symmetrized) from baseline.
Time frame: 2 Weeks
Visual Analog Scale for Sleep Quality
Self-reported sleep quality measured using a visual analog scale. Quantitative outcome variable: absolute change from baseline. Range: 0-10 (higher values indicate greater sleep quality).
Time frame: 2 Weeks