This is a multi-centre, single- arm, non-randomized, open-label phase 1/2 clinical trial which enables dosing of the fellow eyes of patients who received VGR-R01 administration in previous studies.
VGR-R01 is a novel Adeno-associated virus (AAV) vector carrying the human Cytochrome P450 Family 4 Subfamily V Member 2 (CYP4V2) coding sequence. This study will evaluate the safety and efficacy of VGR-R01 administered in the contralateral eye (the second treated eye) of subjects enrolled in the VGR-R01-001 and VGR-R01-101 studies, along with assessments of immunogenicity and vector shedding. Additionally, the long-term safety and efficacy of VGR-R01 treatment will be continuously assessed for up to 5 years after the last dose.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
TREATMENT
Masking
NONE
Enrollment
15
CYP4v2-coding gene delivered by AAV vector
Beijing Tongren Hospital
Beijing, Beijing Municipality, China
Shanghai General Hospital (Shanghai First People's Hospital)
Shanghai, Shanghai Municipality, China
Incidence of adverse events and serious adverse events
Ocular/non-ocular adverse events are collected. The ophthalmic examination will include Best Corrected Visual Acuity (BCVA), Intraocular Pressure (IOP), slit lamp examination, angiography and Optical Coherence Tomography (OCT), etc. If any potential changes accompanied by clinical symptoms, or results in a change of medical intervention, the findings will be considered as clinically significant based on investigator's decision.
Time frame: Up to Year 5
Number of participants with clinically significant change from baseline in vital signs, clinically laboratory abnormalities and ophthalmic examination findings
Vital signs (temperature, respiratory rate, pulse rate, systolic and diastolic blood pressure) will be obtained with participant in the seated position, after having sat calmly for at least 10 minutes. Laboratory Tests will include hematology, coagulation, blood chemistry, urinalysis, serology, and pregnancy test, etc. Ophthalmic Examination will include BCVA, IOP, slit lamp examination, angiography and OCT, etc. Clinical significance of the above signs will be determined at the investigator's discretion.
Time frame: Up to Year 5
Change from baseline in BCVA
BCVA will be assessed with the Early Treatment of Diabetic Retinopathy Study (ETDRS) visual acuity (VA) chart..
Time frame: Year 5
Change from baseline in multi-luminance mobility test (MLMT) score
Subjects will navigate a standardized mobility maze under set conditions as specified times during the study. All light-levels used for testing will be rounded to one of the following specified light levels: 0.1, 1, 4, 10, 50, 125, 250, or 400 lux. The corresponding scores for the above light levels range from 7 to 0, in descending order. -1 point means failing to pass the test at the 400 lux level; the lower the score, the worse the functional vision of the participant.
Time frame: Year 5
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Change from baseline in optical coherence tomography (OCT)
Change from baseline in central retinal thickness (CRT) as imaged by OCT.
Time frame: Year 5
Number of subjects with the presence of immunogenicity
Assessed as presence of systemic cell-mediated or humoral responses to capsid or transgene product.
Time frame: Year 5
Number of subjects with the presence of vector shedding
Assessed as the presence of vector in peripheral blood or collected tear.
Time frame: Year 5
Fixation stability
Number of treated eyes with changes from baseline in fixation stability with MP-3 Microperimetry. Fixation stability is rated into three levels: stable fixation, relatively unstable fixation, and unstable fixation, with fixed standard reporting on the device settings.
Time frame: Year 5
Light sensitivity
Changes from baseline in light sensitivity with MP-3 Microperimetry. The MP-3 has a stimulus intensity range of 0 to 34 decibels (dB).
Time frame: Year 5