The purpose of this study is to compare two different airway pressure (PEEP) strategies during gynecological laparoscopic surgery to see which one better prevents lung collapse (atelectasis). We will compare a 'standard' fixed pressure with a 'personalized' pressure adjusted according to the patient's own lung mechanics (driving pressure). We will use lung ultrasound to check the lungs before surgery, 1 hour after surgery, and 24 hours after surgery to evaluate the results.
In this prospective observational study, we investigate the impact of PEEP strategies on lung collapse (atelectasis) in patients undergoing gynecological laparoscopy. The Standard Group receives a routine clinical application of 5 cmH2O PEEP. The Individualized Group undergoes a PEEP titration protocol where PEEP starts at 20 cmH2O and is adjusted to reach the optimal level based on the lowest driving pressure. To measure the results, a 12-zone Lung Ultrasonography (LUS) scoring system (0-3 points per zone) is utilized. Evaluations are conducted preoperatively (baseline), 1 hour postoperatively (early phase), and 24 hours postoperatively (late phase) to track the development and resolution of atelectasis.
Study Type
OBSERVATIONAL
Enrollment
72
Etlik City Hospital
Ankara, Turkey (Türkiye)
Lung Ultrasonography (LUS) Score
Atelectasis severity is assessed using a 12-zone Lung Ultrasonography (LUS) scoring system. Each zone is scored from 0 to 3 (0=normal aeration, 3=consolidation). The total score ranges from 0 to 36. Higher scores indicate worse lung aeration and more severe atelectasis.
Time frame: Preoperatively (baseline), 1 hour postoperatively, and 24 hours postoperatively.
Correlation Between Intraoperative Ventilation Parameters and Early Postoperative LUS Scores
Evaluation of the relationship between intraoperative respiratory parameters (Peak Airway Pressure \[Ppeak\], Plateau Pressure \[Pplat\], and Compliance) and early postoperative lung aeration assessed by Lung Ultrasonography (LUS) in the Post-Anesthesia Care Unit (PACU).
Time frame: From the start of anesthesia until 1 hour postoperatively.
Correlation Between Intraoperative Ventilation Parameters and Postoperative Oxygenation
Evaluation of the relationship between intraoperative respiratory parameters (Ppeak, Pplat, and Compliance) and postoperative peripheral oxygen saturation (SpO₂) in the PACU.
Time frame: From the start of anesthesia until 1 hour postoperatively.
Correlation Between Intraoperative Ventilation Parameters and Early Postoperative Pulmonary Complications
Evaluation of whether intraoperative respiratory parameters (Ppeak, Pplat, and Compliance) are associated with the development of clinical pulmonary complications within the first 24 hours.
Time frame: From the start of anesthesia up to 24 hours postoperatively.
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.