This prospective, single-center clinical investigation conducted in France will evaluate two non-invasive investigational devices (HEMI and SPG-NINOX) designed to assess microcirculation in adults. The study will include 165 participants divided into five groups (33 per group): healthy volunteers, patients with hypertension without chronic kidney disease (CKD), patients with type 2 diabetes without CKD, patients with moderate CKD, and patients with severe CKD. The primary objective is to compare baseline small vessel pressure measured with the HEMI (Multi-spectral optical system for microcirculation hemodynamics) device across groups in order to identify microvascular alterations associated with cardiometabolic and renal disease. Secondary objectives include assessment of microvascular responses after post-ischemic hyperemia, evaluation of SPG-derived (Speckle plethysmography) small vessel flow and volume parameters, comparison with reference vascular measurements (including SphygmoCor and ultra-high frequency ultrasound), and evaluation of feasibility, acceptability, and measurement reproducibility. Participation is non-randomized, based on participants' pre-existing clinical condition, and study procedures are non-invasive with an expected visit duration of approximately 60 minutes.
Study Type
INTERVENTIONAL
Allocation
NON_RANDOMIZED
Purpose
BASIC_SCIENCE
Masking
NONE
Enrollment
165
Non-invasive investigational device used to assess microcirculation through physiological signal acquisition and derivation of microvascular parameters, including small vessel pressure at baseline. Measurements are performed during a single study visit under standardized conditions. In predefined subgroups, additional measurements may be performed after post-ischemic hyperemia and for reproducibility assessment.
Non-invasive investigational device used to assess microcirculation through physiological signal acquisition and derivation of microvascular parameters, including small vessel flow and volume-related measures. Measurements are performed during a single study visit under standardized conditions.
INSERM U970, Equipe 7, 56 rue Leblanc
Paris, France
HEMI-derived small vessel pressure at baseline
Small vessel pressure derived from the HEMI non-invasive investigational device under standardized resting conditions at baseline. The primary analysis compares values across the five study groups.
Time frame: Baseline (single study visit, approximately 60 minutes)
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.